Cable Removed Or Power Loss - Oracle SPARC Enterprise M4000 Installation And Service Manual

External i/o expansion unit
Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

A link card has failed.
Resolution
1. See
Bridge Controller timeouts.
2. Replace the link cable.
3. Replace the link card in the I/O boat.
4. Replace the link card in the host.
D.2.4

Cable Removed or Power Loss

MSGID IOXSCF-8000-84 fault.chassis.iox.device.missing
The service processor detects loss of both the management bus and PCI Express data
path to an External I/O Expansion Unit. This failure occurs only if the host was
already managing External I/O Expansion Unit. See
Failures" on page D-15
Possible Causes
The PCI Express cable is unplugged.
There is a loss of input power to the External I/O Expansion Unit.
The I/O boat was removed while in use.
The cable is faulty.
The link card in the host is faulty.
The link card in the I/O boat is faulty.
Resolution
1. Check the cable connection.
If cable had been unplugged, make sure the link cables are reconnected correctly.
2. Check input power to the External I/O Expansion Unit.
3. Try a different cable to determine if a similar failure occurs.
Section D.2.7.4, "Bridge Controller Timeout" on page D-21
for details on FRU discovery failures.
for details on
Section D.2.6, "FRU Discovery
Appendix D
Troubleshooting
D-13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPARC Enterprise M4000 and is the answer not in the manual?

Table of Contents