Overview - Valor 1100JN Installation & Owner's Manual

H5 series, direct vent zero clearance gas fireplaces, natural/propane gas
Table of Contents

Advertisement

Remote Handset
Wall Holder
T
T
T
T
T
ri
i
i
i m m
i
wi
i t
it
ith
h
h
h
B
B
B
B
arri
i er
i
i
S creen
S
S
S
(required)
Fixed Framing kit
( ( 1130FFK) installs at
framing stage and
allow w s non-combustible
w
w
w all fi nish to fi nish up to
i
i t. All other trims overlap
th h e surrounding non-
com m bustible wall fi nish
a a nd are adjustable to
a a ccomodate material
up to 3/4" thickness
overtop of the base
1/ / 2" non-combustible
board. For material
thi i ckness greater than
3/4", the heater requires
r r epositioning further
forward in the framing
cavity
y
—see p
p
ag
g
g
e 49
W
W
W
W
all
l l
l
ll
F
F
F
F
i
i
i
i
ni
i
i
i
sh
h
h
h
Any wall fi nishes
applied over non-
combustible board
must be also
non-combustible.
C C ombustible mantels
a a re ok provided they
conform to chart
on p
p
p
p
p
p
p
p
p
ag
g
g
g
g
g
g
g
g
g
e 25
Combustible
Non-combustible Hearth—
Floor
See Hearth Requirements
WARNING
!
Some materials or items, although safe,
may discolor, shrink, warp, crack, peel, and
so on because of the heat produced by the
fi replace. Avoid placing candles, paintings,
photos, and other items sensitive to heat
around the fi replace.

Overview

Note: This appliance may be installed in outdoor,
weather protected environments as defi ned in the
GV60CKO Outdoor Conversion Kit instruction manual.
Mantel—See Mantel & Hearth Clearances
Framing—See Framing Requirements
1/2 inch thick non-combustible board
or equivalent – NOT supplied—see
page 31 for board specifi cations
Supplied as vertical outlet, fi eld
convertible to horizontal outlet.
1/2" Micore supplied
with unit. Use as a
thermal break between
non-combustible hearth
material and combustible
material underneath.
HOT WALL SURFACES! The wall directly
above the fi replace is constructed of non-
combustible materials and, although safe, it
may reach temperatures in excess of 200° F
depending on choice of trims. Do not touch.
Finish the wall using materials suitable for
these temperatures.
Optional LDK HeatShift
Duct Kit outlets (4)
1100J or
1150J
heater
Combustible Framing Allowed Beneath Fireplace.
When the appliance is installed directly on
carpeting, tile or other combustible material other
than wood fl ooring, the appliance shall be installed
on a metal or wood panel extending the full width
and recessed depth of the appliance.
WARNING
!
QUALIFIED
INSTALLER
Remote Battery
and Wall Switch
Kit (required)
(35-foot
wire length)
(supplied)
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1150jlp1100jp1150jln

Table of Contents