Planning Wall Finish - Valor 1100JN Installation & Owner's Manual

H5 series, direct vent zero clearance gas fireplaces, natural/propane gas
Table of Contents

Advertisement

QUALIFIED
INSTALLER

Planning Wall Finish

Non-combustible cement board
The H5 fi replace requires a 1/2" (13 mm) thick
non-combustible cement board or equivalent,
to be used as a wall surface immediately above
the unit—see diagram for minimum coverage.
Extending the cement board well beyond the
minimum shown will help avoid cracking due
to diff erential expansion of materials. Pre-drill
cement board with oversized holes and do not
over-tighten screws to avoid cracking due to
heat expansion.
Standard gypsum wall board may be used
beyond the perimeter of the cement board
although it is preferable not to change
materials to help avoid cracking.
Finishing around trims
Additional non-combustible material such as tile,
etc., may be applied over top of the wall surface
or you may choose to leave it fi nished clean with
no tile, etc.—see page 43.
Be aware that a trim is always required and
that the wall fi nish thickness must be taken into
account for all installations other than the Fixed
Framing Kit 1130.
All the other trims, 1135, 1140, 1149 and 1184
will accept wall fi nish tucked under their edge up
to approximately 2" thick.
Non-Combustible Materials Specifi cations
Material which will not ignite and burn. Such materials
are those consisting entirely of steel, iron, brick, tile,
concrete, slate, glass or plasters, or any combination
thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 °C shall be considered
non-combustible materials.
Combustible Materials Specifi cations
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that
can ignite and burn, whether fl ame proofed or not,
or plastered or unplastered shall be considered
combustible materials.
42
Installation Planning
Gypsum board
up to perimeter of
non-combustible board
Min.
12"
(305 mm)
Minimum cement board
dimensions
1130FFK
Fixed Framing Kit
Min. 39-1/2"
(1003 mm)
1/2" (13mm) thick
non-combustible
cement board
1135TSB 3-sided trim 1140FSB 4-sided trim
1184EH Edgemont
1149EDV Edgemont
Hammered Kit