Positioning Extension Setting Servo Parameters Group ([Pr. Pv; [Pr. Pv01_Profile Speed Command Extension Setting (Pvc2)]; [Pr. Pv03_Maximum Profile Speed Extension Setting (Mpvce)]; [Pr. Pv05_Profile Acceleration (Pacc)] - Mitsubishi Electric Melservo-Jet MR-JET-G User Manual

Ac servo system, parameters
Hide thumbs Also See for Melservo-Jet MR-JET-G:
Table of Contents

Advertisement

1.11
Positioning extension setting servo parameters
group ([Pr. PV_ _ ])

[Pr. PV01_Profile speed command extension setting (PVC2)]

Initial value
0 [Refer to the text below for the unit.]
Set the speed command used in the profile position mode (pp).
The unit is [pulse/s].
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1". This function and [Pr.
PT65 Profile speed command] are mutually exclusive.
The setting value will be clamped at the maximum speed. When changing the speed to the permissible speed, set the speed
in [Pr. PA28.4 Speed range limit selection].
This function corresponds to [Profile velocity (Obj. 6081h)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.

[Pr. PV03_Maximum profile speed extension setting (MPVCE)]

Initial value
2147483647 [Refer to the text below for the unit.]
Set the speed limit value of the profile position mode (pp) and the profile velocity mode (pv).
The unit is [pulse/s].
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1". This function and [Pr.
PT66 Maximum profile speed] are mutually exclusive.
This function corresponds to [Max profile velocity (Obj. 607Fh)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.

[Pr. PV05_Profile acceleration (PACC)]

Initial value
0 [Refer to the text below for the unit.]
Set the acceleration used in the profile position mode (pp) and the profile velocity mode (pv).
2
The unit is [pulse/s
].
When the setting value of this servo parameter is "0", the servo motor accelerates in accordance with the time constant set in
[Pr. PT49 Speed acceleration time constant].
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1". This function and [Pr.
PT49] are mutually exclusive.
This function corresponds to [Profile acceleration (Obj. 6083h)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.
Setting range
0 to 4294967295
Setting range
0 to 4294967295
Setting range
0 to 4294967295