Adjusting The Ribbon Controller (Calibration) - Roland V-Bass VB-99 Owner's Manual

Roland v-bass system owner's manual
Hide thumbs Also See for V-Bass VB-99:
Table of Contents

Advertisement

Chapter 7 Other Functions
4.
To turn off the D Beam controller, press the
button you pressed in Step 1 again so the
indicator goes off.
Effective Range of the D Beam Controller
The D Beam controller's effective range is shown in the figure
below. Moving your hand outside this effective range produces
no effect.
The effective range of the D Beam controller will be
extremely limited when used under strong, direct
sunlight. Please be aware of this when using the D
Beam controller outdoors.
The sensitivity of the D Beam controller can vary
depending on the amount of light in the vicinity of
the unit. If it does not function as you expect, adjust
the D Beam.(p. 70)
The parameter values set by holding your hand or
other object over the D Beam controller change as
shown below.
D BEAM vertical
Explanation
movements
Closer to the D Beam
The value approaches the MAX value.
Farther from the D
The value approaches the MIN value.
Beam
D BEAM horizontal
Explanation
movements
To the right of the D
The value approaches the MAX value.
Beam
To the left of the D
The value approaches the MIN value.
Beam
72
Adjusting the Ribbon Controller
(CALIBRATION)
While the ribbon controller has been adjusted at the factory for
optimum performance, the responsive range may vary with the
width of the finger used to activate the controller.
If this occurs, use the procedure below to readjust the range.
1.
Press [SYSTEM].
2.
Press PAGE [
] [
3.
Press [F6] (CALIB).
4.
Press PAGE [
] to go to Page 2.
The RIBBON CALIB screen appears.
5.
Set the responsive range as you actually
operate the ribbon controller.
• First, while holding your finger against the near end of the
ribbon controller, press [F1] (SetMIN).
• Next, hold your finger against the far end and press [F4]
(SetMAX).
If the message "OUT OF RANGE! SET AGAIN." is displayed,
carry out the calibration process once more. If the message
continues to appear even after the calibration is correctly
performed, it may indicate damage or malfunction. Consult
your Roland dealer or contact Roland Service.
6.
Press [EXIT] several times to return to the Play
screen.
The CALIBRATION setting is a system parameter, so the
Write procedure is not required.
] to go to Page 2.

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-bass 04672434

Table of Contents