lldp holdtime-multiplier

Supported on:
MSM710 E-MSM720 MSM760 MSM765zl
lldp holdtime-multiplier <hold>
Sets the hold time multiplier for LLDPDU transmissions.
The value of Multiplier is multiplied by the refresh-interval to define Time to live. Time to live
indicates the length of time that neighbors will consider LLDP information sent by this agent to be
valid.
lldp med-location civic-address-element
Supported on:
MSM710 E-MSM720 MSM760 MSM765zl
lldp med-location civic-address-element <caelement>
Adds a Civic Address Element.
lldp med-location elin-addr
Supported on:
MSM710 E-MSM720 MSM760 MSM765zl
lldp med-location elin-addr <elin>
Sets the Emergency Call Services ELIN as described, for example, by NENA TID 07-501.
lldp refresh-interval
Supported on:
MSM710 E-MSM720 MSM760 MSM765zl
lldp refresh-interval <time>
Sets the interval (in seconds) at which local LLDP information is updated and TLVs are sent to
neighboring network devices.
lldp run
Supported on:
MSM710 E-MSM720 MSM760 MSM765zl
lldp run
Enables the LLDP Agent.
no lldp run
Disables the LLDP Agent.
show lldp config
Supported on:
MSM710 E-MSM720 MSM760 MSM765zl
show lldp config [<port>]
Displays LLDP configuration settings.
show lldp info local-device
Supported on:
MSM710 E-MSM720 MSM760 MSM765zl
show lldp info local-device [<port>]
Displays LLDP configuration settings.