OVS 4CH-P4 Quick Operation Manual page 232

8700-p series
Table of Contents

Advertisement

User Manual
User Manual of 87XX-P Series NVR
Select "Menu>Camera>Camera>IP Camera" to get the camera status.
Possible Reasons
a)
b)
c) Insufficient bandwidth.
Steps
1. Verify the network is connected.
1) Connect the NVR and PC with the RS-232 cable.
2) Open the Super Terminal software, and execute the ping command. Input "ping IP" (e.g. ping
2. Verify the configuration parameters are correct.
1) Select "Menu>Camera>Camera>IP Camera".
2) Verify the following parameters are the same with those of the connected IP devices, including IP
3. Verify the whether the bandwidth is enough.
1) Select "Menu >Maintenance > Net Detect > Network Stat.".
2) Check the usage of the access bandwidth, and see if the total bandwidth has reached its limit.
4. Check if the fault is solved by the step 1 to step 3.
If it is solved, finish the process.
If not, please contact the engineer to do the further process.
The IPC frequently goes online and offline and the status of it displays as "Disconnected".
Possible Reasons
a)
b)
c) Unstable network between IPC and NVR.
d)
Steps
1. Verify the IPC and the NVR versions are compatible.
1) Enter the IPC Management interface "Menu > Camera > Camera>IP Camera", and view the firmware
2) Enter the System Info interface "Menu>Maintenance>System Info>Device Info", and view the firmware
2. Verify power supply of IPC is stable.
1) Verify the power indicator is normal.
2) When the IPC is offline, please try the ping command on PC to check if the PC connects with the IPC.
3. Verify the network between IPC and NVR is stable.
1) When the IPC is offline, connect PC and NVR with the RS-232 cable.
2) Open the Super Terminal, use the ping command and keep sending large data packages to the
4. Verify the switch is not flow control.
Network failure, and the NVR and IPC lost connections.
The configured parameters are incorrect when adding the IPC.
172.6.22.131).
Note:
Simultaneously press Ctrl and C to exit the ping command.
If there exists return information and the time value is little, the network is normal.
address, protocol, management port, user name and password.
The IPC and the NVR versions are not compatible.
Unstable power supply of IPC.
Limited flow by the switch connected with IPC and NVR.
version of connected IPC.
version of NVR.
connected IPC, and check if there exists packet loss.
Note:
Simultaneously press Ctrl and C to exit the ping command.
Example: Input ping 172.6.22.131 –l 1472 –f.