Table 3. Firmware Error Codes. (continued)
Error Code Description
40D00003 An unknown slow shutdown
occurred.
40D00004 An unknown fast shutdown
occurred.
40D00101 BIST on I/O board failed.
40D00102 BIST on system board failed.
40D00200 Processor array initialization
failed.
40D00201 JTAG chip ID miscompare.
450000C0 Uncorrectable memory error
(checkstop).
450000C1 Memory ECC correctable error
(checkstop).
Action / Possible Failing FRU
Critical cooling problem. Check to
ensure the temperature is in the
ambient range.
Locked fan failure detected. Make sure
all fans are operating normally.
Replace I/O board. (See note on page
93.)
Replace system board.
Location code will point to failing FRU.
Location code will point to failing FRU.
1. If a physical location code is
displayed in the operator panel or
by AIX diagnostics, replace the FRU
as indicated by the location code. If
a physical location code is not
available, continue.
2. In the service processor menus, go
to "Read Progress Indicators from
last System Boot". If an arrow is
pointing to a location code replace
the FRU at that location code. If
there is no arrow pointing to a
location code, continue.
3. Go to "MAP 1540: Minimum
Configuration" on page 50.
1. If a physical location code is
displayed in the operator panel or
by AIX diagnostics, replace the FRU
as indicated by the location code. If
a physical location code is not
available, continue.
2. In the service processor menus, go
to "Read Progress Indicators from
last System Boot". If an arrow is
pointing to a location code replace
the FRU at that location code. If
there is no arrow pointing to a
location code, continue.
3. Go to "MAP 1540: Minimum
Configuration" on page 50.