IBM RS/6000 44P 270 Service Manual page 125

Rs/6000 44p series
Hide thumbs Also See for RS/6000 44P 270:
Table of Contents

Advertisement

Table 3. Firmware Error Codes. (continued)
Error Code Description
26800Cxx Machine check occurred.
26800Dxx Machine check occurred, unable
to isolate to single device
28030xxx RTC errors
28030001 RTC initialization required-RTC
not updating, corrected.
Action / Possible Failing FRU
If the location code shown on the
operator panel identifies a card slot:
1. Replace the adapter in the slot
identified.
2. Replace the I/O board (See note on
page 93.)
If the location code shown does not
identify a card slot, or if there is no
location code, replace the I/O board.
(See note on page 93.)
"xx" indicates the PCI bus number with
the error
1. Attempt to reboot the system in
service mode; this preserves the
AIX error log. If the reboot is
successful, run diagnostics in
problem determination mode to
determine the cause of failure.
Otherwise continue.
2. Refer to the "Bus SRN to FRU
Reference Table" page 123, using
PCI Bus "xx" for isolation of the
failing device.
1. Errors reported against the real time
clock (RTC) can be caused by low
battery voltage and (more rarely)
power outages that occur during
normal system usage. These errors
are warnings that the RTC data
content had to be re-established
and do not require any FRU
replacement unless the error is
persistent. When one of these
errors occurs, the power-on
password and time and date
information has been lost.
v To set/restore a power-on
password, use the SMS utility.
v To set/restore the time and date,
use the operating system facility.
2. If the error is persistent, replace the
battery.
3. If the error is persistent after battery
replacement, replace the I/O board.
(See note on page 93.)
Refer to Action under error code
28030xxx.
Chapter 5. Error Code to FRU Index
107

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7044-270

Table of Contents