Table 3. Firmware Error Codes. (continued)
Error Code Description
2BA00309 Service processor reports generic
cooling alert.
2BA00310 Service processor reports
processor card over temperature
alert.
2BA00311 Service processor reports I/O
over temperature alert.
2BA00312 Service processor reports
memory over temperature alert.
2BA00313 Service processor reports generic
power alert.
2BA00314 Service processor reports 5V over
voltage alert.
2BA00315 Service processor reports 5V
under voltage alert.
2BA00316 Service processor reports 3.3 V
over voltage alert.
2BA00317 Service processor reports 3.3 V
under voltage alert.
2BA00318 Service processor reports 2.5 V
over voltage alert.
2BA00319 Service processor reports 2.5 V
under voltage alert.
2BA00320 Service processor reports +12 V
over voltage alert.
2BA00321 Service processor reports +12 V
under voltage alert.
2BA00322 Service processor reports -12 V
over voltage alert.
Action / Possible Failing FRU
1. Check for cool air flow obstructions
to the system.
2. Replace I/O board. (See note on
page 93.)
1. Check for cool air flow obstructions
to the system.
2. If the problem persists, replace
processor card.
1. Check for cool air flow obstructions
to the system.
2. Replace I/O board. (See note on
page 93.)
1. Check for cool air flow obstructions
to the system.
2. Replace memory card.
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
1. Replace power supply.
2. Replace I/O board. (See note on
page 93.)
Chapter 5. Error Code to FRU Index