Fuel Consumption On Idling [L/H] (Id=11907); Higher Speeds Add [%] (Id=11908); Highway Consumption Every Km/H (Id=11909); Scenarios Accelerometer - Teltonika FMB920 User Manual

Fmb900 series
Hide thumbs Also See for FMB920:
Table of Contents

Advertisement

6.9.1.8

Fuel Consumption on Idling [L/h] (ID=11907)

Sets fuel consumption while vehicle is idling
Minimum
Maximum
value
value
0
5
6.9.1.9

Higher Speeds Add [%] (ID=11908)

Minimum
Maximum
value
value
0
250

6.9.1.10 Highway Consumption every km/h (ID=11909)

Minimum
Maximum
value
value
0
100

6.10 Scenarios Accelerometer

6.10.1 Crash Detection

6.10.1.1 Scenario settings (ID=11400)

Sets priority of the scenario: 0 – Disable, 1 – Low Priority, 2 – High Priority, 3 – Panic
Priority
Minimum
Maximum
value
value
0
3

6.10.1.2 Duration [ms] (ID=11401)

Minimum
Maximum
value
value
0
2000

6.10.1.3 Treshold [mG] (ID=11402)

Minimum
Maximum
value
value
0
7900

6.10.1.4 Crash trace (ID=11406)

Minimum
Maximum
value
value
0
1

6.10.1.5 Send sms to (ID=7068)

Enable/disable sms event sending. 0 – Disable, 1-10 – sms will be sent to configured GSM
number. (SMS \ Call Settings -> GSM Predefined Numbers list.)
Minimum Maximum
Default value
Goes with (depends on)
1
Default value
Goes with (depends on)
20
Default value
Goes with (depends on)
50
default value
Goes with (depends on)
0
default value
Goes with (depends on)
5
default value
Goes with (depends on)
1500
default value
Goes with (depends on)
0
default value
Goes with (depends on)
parameters
parameters
parameters
parameters
parameters
parameters
parameters
Value
type
Double
Value
type
Unit64
Value
type
Unit64
Value
type
U64
Value
type
U64
Value
type
U64
Value
type
U64
Value
80