value
value
0
2592000
6.6.2

Home Network GSM operator code "Vehicle MOVING" parameters

6.6.2.1 Min Period (ID=10050)

This parameter indicates time interval in seconds in order to acquire new record. If value is
0 it means no records by min period will be saved.
Minimum
Maximum
value
value
0
2592000

6.6.2.2 Min Distance (ID=10051)

This parameter indicates distance in meters in order to acquire new record. Record is
stored when the distance between previous records is greater than parameters value. If value is
0 it means no records by min distance will be saved.
Minimum
Maximum
value
value
0
65535

6.6.2.3 Min Angle (ID=10052)

This parameter indicates angle in degrees in order to acquire new record. If angle
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. This parameter is operational, when speed is higher than 10km/h. If value
is 0 it means no records by min angle will be saved.
Minimum
Maximum
value
value
0
180

6.6.2.4 Min Speed delta (ID=10053)

This parameter indicates speed difference in order to acquire new record. If speed
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. If value is 0 it means no records by min distance will be saved.
Minimum
Maximum
value
value
0
255
value
-
Min Saved Records (ID=10004)
Recommended
value
-
Recommended
Goes with (depends on)
value
-
Recommended
Goes with (depends on)
value
-
Min Distance (ID=10051)
Recommended
Goes with (depends on)
value
10
Min Distance (ID=10051)
parameters
Goes with (depends on)
parameters
Min Distance (ID=10051)
Min Angle (ID=10052)
parameters
Min Period (ID=10050)
Min Angle (ID=10052)
parameters
Min Period (ID=10050)
parameters
Min Period (ID=10050)
Min Angle (ID=10052)
type
U32
Value
type
U32
Value
type
U32
Value
type
U16
Value
type
U16
67