Configuration Example Of Inter-As Mpls Te Tunnel Using Rsvp-Te - H3C SR8800 10G Mpls Configuration Manual

Core routers
Table of Contents

Advertisement

Configuration example of inter-AS MPLS TE tunnel using
RSVP-TE
Network requirements
Router A and Router B are in AS 100, and they run OSPF as the IGP. Router C and Router D are in AS
200, and they run OSPF as the IGP.
Establish an EBGP connection between ASBRs Router B and Router C. Redistribute BGP routes into OSPF
and OSPF routes into BGP, so that a route is available between AS 100 and AS 200.
Establish an MPLS TE tunnel between Router A and Router D by using RSVP-TE, with the bandwidth being
2000 kbps.
Along the tunnel, the maximum link bandwidth is 10000 kbps and maximum reservable bandwidth is
5000 kbps.
Figure 26 Network diagram
Device
Router A
Router B
Configuration procedure
Assign IP addresses and masks to interfaces (see
1.
Configure OSPF to advertise routes within the ASs
2.
# Configure OSPF on Router A.
<RouterA> system-view
[RouterA] ospf
[RouterA-ospf-1] area 0
[RouterA-ospf-1-area-0.0.0.0] network 10.1.1.0 0.0.0.255
[RouterA-ospf-1-area-0.0.0.0] network 1.1.1.9 0.0.0.0
[RouterA-ospf-1-area-0.0.0.0] quit
[RouterA-ospf-1] quit
Interface
IP address
Loop0
1.1.1.9/32
GE3/1/1
10.1.1.1/24
Loop0
2.2.2.9/32
GE3/1/1
10.1.1.2/24
POS2/1/1
20.1.1.1/24
Device
Interface
Router C
Loop0
GE3/1/1
POS2/1/1
Router D
Loop0
GE3/1/1
Figure
26)
98
IP address
3.3.3.9/32
30.1.1.1/24
20.1.1.2/24
4.4.4.9/32
30.1.1.2/24

Advertisement

Table of Contents
loading

Table of Contents