Transport And Storage; Safety Information For Electrical Installation; Safety Information For Inspection And Maintenance - ABB 265DS Operating Instruction

265d series differential pressure transmitter
Table of Contents

Advertisement

Safety
Pos: 5.28 /Überschriften/1.1/1-spaltig/S - U/Transport und Lagerung @ 1\mod_1147676028156_3101.doc @ 10771

1.12 Transport and storage

Pos: 5.29 /Transport/Druck/Allgemein/Transport und Lagerung @ 1\mod_1147677516421_3101.doc @ 10843
After unpacking the pressure transmitter, check the device for transport damage.
Check the packaging material for accessories.
During intermediate storage or transport, store the pressure transmitter in the original
packaging only.
For information on permissible ambient conditions for storage and transport, see "Technical
data". Although there is no limit on the duration of storage, the warranty conditions stipulated in
the order confirmation from the supplier still apply.
Pos: 5.30 /Sicherheit/Durchfluss/Allgemein/Sicherheitshinweise zur elektrischen Installation (Durchfluss) @ 0\mod_1129733762419_3101.doc @ 3267

1.13 Safety information for electrical installation

Electrical connections may only be established by authorized specialist personnel in
accordance with the electrical circuit diagrams.
The electrical connection information in the manual must be observed; otherwise, the applicable
protection type may be affected.
Ground the measurement system according to requirements.
Pos: 5.31 /Sicherheit/Druck/Druckmessumformer/Allgemein/Sicherheitshinweise zur Inspektion und Wartung @ 2\mod_1151476841828_3101.doc @ 32114

1.14 Safety information for inspection and maintenance

Warning – Risk to persons
There is no EMC protection or protection against accidental contact when the housing cover is
open. There are electric circuits within the housing which are dangerous if touched.
Therefore, the auxiliary power must be switched off before opening the housing cover.
Warning – Risk to persons
The device can be operated at high pressure and with aggressive media. Any medium that
squirts out can cause severe injuries.
Depressurize the pipeline/tank before opening the transmitter connection.
Corrective maintenance work may only be performed by trained personnel.
Before removing the device, depressurize it and any adjacent lines or containers.
Check whether hazardous materials have been used as materials to be measured before
opening the device. Residual amounts of hazardous material may still be present in the
device and could escape when the device is opened.
Within the scope of operator responsibility, check the following as part of a regular
inspection:
− Pressure-bearing walls/lining of the pressure device
− Measurement-related function
− Leaktightness
− Wear (corrosion)
Pos: 6 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830