Mounting Dimensions (Not Design Data); Differential Pressure Transmitter With Barrel Housing - ABB 265DS Operating Instruction

265d series differential pressure transmitter
Table of Contents

Advertisement

Pos: 23.59 /Überschriften/1.1/1-spaltig/M - O/Montageabmessungen (keine Konstruktionsangaben) @ 1\mod_1149058512625_3101.doc @ 27748

10.8 Mounting dimensions (not design data)

Pos: 23.60 /Überschriften/1.1.1/1-spaltig/Differenzdruckmessumformer mit Barrel-Gehäuse @ 17\mod_1201169114234_3101.doc @ 154052

10.8.1 Differential pressure transmitter with barrel housing

Pos: 23.61 /Technische Daten / Datenblatt/Druck/Druckmessumformer/Druckmessumformer 265Dx, 265Vx/Maßzeichnungen/Messumformer mit Barrel-Gehäuse @ 5\mod_1165223965343_3101.doc @ 50073
114 (4.49)
9 (0.35)
1
2
3
4
54 (2.13)
96 (3.78)
71 (2.80)
10
11
12
Fig. 23: Dimensions in mm (inches), deviations in the drawing are possible
1
Terminal side
2
Housing stop-screw
3
Sensor plate
4
Process connection (conforms to IEC 61518)
5
With LCD display
6
Space for removing the cover required
7
Additional tag plate, e. g. for marking measuring points (optional)
8
Drain/vent valve (optional)
9
Thread for fixing screws
(see "Process connections" data)
Pos: 23.62 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830
IM/265D/V-EN-02
23 (0.91)
58 (2.28)
7
8
-
+
9
13
14
5
20 (0.79)
6
10 Electrical connection
11 Name plate
12 Housing cover
13 Plate with key legend, etc.
14 Captive fixing screw for keyboard cover
15 Space for rotating the keyboard cover required
16 Upper or lower threaded bore (optional); 1/4-18 NPT for
drain/vent valve
265Dx, 265VS
Technical data
15
16
90 (3.54)
M00160
75