Use in explosion-proof areas
Pos: 7.16 /Überschriften/1.1/1-spaltig/V - Z/Zündschutzart Eigensicherheit, druckfeste Kapselung und energiebegrenzte Betriebsmittel @ 3\mod_1157964815781_3101.doc @ 41176
2.6
Explosion protection types "Intrinsically safe", "Flameproof enclosure", and "Limited energy
equipment"
Pos: 7.17 /Ex-technische Sicherheitshinweise/Druck/Druckmessumformer/Allgemein/Zündschutzart Eigensicherheit, druckfeste Kapselung und energiebegrenzte Betriebsmittel @ 3\mod_1157963542656_3101.doc @ 41071
Alternative certification:
Intrinsically safe
Flameproof enclosure
Limited energy equipment
Important
Prior to commissioning, the selected type of explosion protection (only one may be selected)
must be permanently marked in the appropriate box on the name plate. Once selected, the
type of explosion protection may not be changed.
If a supply is not intrinsically safe, or the transmitter has been fed in a way that is not intrinsically
safe, the explosion protection type "Intrinsically safe" is no longer valid.
Caution - Risk
Failure to observe this information will have an adverse effect on explosion protection.
Appropriate cable and wire entries must be used depending on the explosion protection type
selected:
Explosion protection type
II 1/2 G EEx i
II 1/2 D EEx i
II 1/2 G EEx d
II 1/2 D EEx d
II 3 G EEx n
II 3 D EEx n
Pos: 7.18 /Überschriften/1.1/1-spaltig/J - L/Kanadischer Standard CSA - explosion proof @ 3\mod_1157964979734_3101.doc @ 41197
2.7

Canadian Standards Association (CSA): "Explosion-proof"

Pos: 7.19 /Ex-technische Sicherheitshinweise/Druck/Druckmessumformer/Allgemein/Kanadischer Standard CSA - explosion proof @ 3\mod_1157963634125_3101.doc @ 41092
Caution - Potential damage to parts
Transmitters with LCD displays must not be used in etherized atmospheres.
Pos: 7.20 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830
18
(Category 1/2, EEx i) or
(Category 1/2, EEx d), or
(Category 3, EEx nL)
Cable gland
(minimum requirement)
IP 54
IP 6x
EEx d
EEx d and IP 6x
EEx e
EEx e and IP 6x
265Dx, 265VS
IM/265D/V-EN-02