Wiring Requirements; Spare Parts - Ingeteam Ingecon Sun 3.6TL U Installation Manual

Table of Contents

Advertisement

Installation manual

Wiring requirements

The correct wiring of the equipment to any PV installation will be done with the following types of wire:
AC Terminals Ingecon
Sun LITE U
®
Use 6 AWG (maximum), 90 °C (194 °F), copper wire for all AC wiring connections:
The wiring must comply with the provisions of the National Electrical Code ANSI/NFPA70, Canadian Electrical Code
CEC and other Local or State Codes.
DC Terminals Ingecon
Sun LITE U
®
Use 16 to 6 AWG (maximum), 90 °C (194 °F), copper wire for all DC wiring connections.
The wiring must comply with the provisions of the National Electrical Code ANSI/NFPA70, Canadian Electrical Code
CEC and other Local or State Codes.
Tightening torques
AC Terminals Ingecon
Sun LITE U
®
With 6/AWG, maximum tightening torque of 18.6 Nm.
DC Terminals Ingecon
Sun LITE U
®
Maximum tightening torque depending on the wiring:

Spare parts

During the life of the Ingecon
some parts. The parts must be the same as specified in the following list: manufacturer, model and technical
specifications:
Name
Fuse F1, F2
Inverter Marking
The advisory marks of the inverter are:
Grounding Terminal
AAY2000IKI02
Wiring
Maximum tightening torque
16/AWG
10/AWG
8/AWG
6/AWG
Sun Lite, it might be needed to perform some maintenance that could require replacing
®
Manufacturer /
Type / model
trademark
LITTLEFUSE
KLKD001.T
FERRAZ
BUSSMAN
9 Nm
9 Nm
9 Nm
18.6 Nm
Technical data and
securement means
AC/DC Fast-acting
1 A 600 V
AC/DC Fast-acting
ATM1
1 A 600 V
AC/DC Fast-acting
DCM-1
1 A 600 V
RISK OF ELECTRIC SHOCK
Ingeteam Inc
Mark(s) of conformity
vii

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ingecon sun 5 uIngecon sun 5tl uIngecon sun 6tl u

Table of Contents