Environmental Characteristics; Emc Requirements - Ingeteam Ingecon Sun 3.6TL U Installation Manual

Table of Contents

Advertisement

Installation manual
For transformer based models, the transformer is first
secured to the wall and then the inverter is attached
to the transformer.
First, the three holes should be drilled in the top.
The figure provides the hole dimensions. The lower
hole should be made when the unit is hung on the
wall, as explained in section "5.2. Wall mounting
the equipment". The figure shows the approximate
distances between the horizontal line comprising the
three top holes and the position of the lower hole. The
approximate vertical distance to the upper edge of the
inverter which will subsequently be attached to the
transformer secured to the wall.

2.2. Environmental characteristics

The environmental operating conditions are:
Minimum temperature: -4 ºF (-20 ºC).
Minimum temperature of the surrounding air: -4 ºF (-20 ºC).
Maximum temperature of the surrounding air: 158 ºF (70 ºC).
Maximum relative humidity without condensation at 95 %.
Further information in "3. Operating, storage and transport conditions".

2.3. EMC Requirements

The Ingecon
Sun Lite U system is equipped with the necessary filter devices to ensure that it complies with the EMC
®
requirements for industrial applications, thereby preventing disturbances in external equipment.
AAY2000IKI02
Ingeteam Inc
17