Procedure For Clearing The Error Memory On Hitachi Sj100 Inverter; Procedure For Clearing Parameters On Hitachi Sj100 Inverter - Technogym Spazio Forma Service Maintenance Manual

Hide thumbs Also See for Spazio Forma:
Table of Contents

Advertisement

11.3. PROCEDURE FOR CLEARING THE ERROR MEMORY ON
HITACHI SJ100 INVERTER
For all Hitachi SJ100 inverters, it is available an easy procedure for clearing the error memory. To
do this:
1. Turn on the machine;
2. Configure parameter b84 = 00;
3. Come back to the visualization of the parameter b84 and press simultaneously the keys FUNC,
↑ ↑ ↑ ↑ , ↓ ↓ ↓ ↓ ;
4. Holding down the three keys, press also Stop/Reset key for about 1 second and wait for about 3
seconds, until the blinking d00 is shown on the display.
5. Now release all keys again. The initializing phase that now begins will be complete as soon as
the display 00 appears. The errors' memory now will be clear.
11.4. PROCEDURE FOR CLEARING PARAMETERS ON
HITACHI SJ100 INVERTER
For all Hitachi SJ100 inverters, it is available an easy procedure for resetting parameters to the
factory setting. To do this:
1. Turn on the machine;
2. Configure parameter b85 = 01;
3. Configure parameter b84 = 01;
4. Come back to the visualization of the parameter b84 and press simultaneously the keys FUNC,
↑ ↑ ↑ ↑ , ↓ ↓ ↓ ↓ ;
5. Holding down the three keys, press also Stop/Reset key for about 1 second and wait for about 3
seconds, until the blinking d00 is shown on the display;
6. Now release all keys again. The initializing phase that now begins will be complete as soon as
the display 00 appears. The parameters will be reset to the factory setting.