7.17. DISASSEMBLING THE COLUMN AND RUBBER GUARD

Figure 7.17-1
Figure 7.17-2
Page 7.22
SPAZIO FORMA: Service & Maintenance manual - rev. 1.0
1. Carry out the procedure described in
paragraph 7.8. "Disassembling the motor
guard".
2. Raise the machine to its maximum incline
position.
3. Unplug the connectors indicated in the
figure.
4. Back off the 2 nuts b using a 17-mm wrench.
5. Remove the COLUMN by lifting it upward.
6. Remove the RUBBER GUARD a.
Be careful not to damage the finish of
the column.
To reassemble the COLUMN, carry out the
above steps in reverse order.
Before resting the COLUMN on the
frame, remember to insert the rubber
guard.