Technogym Spazio Forma Service Maintenance Manual page 75

Hide thumbs Also See for Spazio Forma:
Table of Contents

Advertisement

SPAZIO FORMA: Service & Maintenance manual - rev. 1.0
Change the receiv er
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
See paragraph 5.1. "Specifications and requirements".
(2)
See paragraph 11.1. "Technical notes on cardio receivers".
(3)
See paragraph 11.1. "Technical notes on cardio receivers".
(4)
To check for electromagnetic noise near the machine, use a frequency signal monitor
constructed as shown in the schematic below:
The circuit lights the LED for every heart beat and/or disturbance that is received: in this way
it possible to determine whether there is any interference, and identify its sources.
(5)
Check the battery power level, using a tester if possible. Otherwise use a receiver or another
"reference" machine to check operation up to a distance of about 80 cm from the receiver.
ATTENTION: Consult paragraph 11.1. "Technical notes on cardio receivers".
A
Is the transmitter in good
working order?
YES
YES
Is the transmitter alway s within
a distance of 80 cm f rom the
receiv er?
5
NO
Use a known good
transmitter
NO
Keep the transmitter
within the minimum
reception distance
Page 6.39