NEC Express5800/R310e-E4 Maintenance Manual page 108

Express5800 series
Hide thumbs Also See for Express5800/R310e-E4:
Table of Contents

Advertisement

Chapter 1 Maintenance
[?]
srae1rexpress or sraixgbt logs are recorded in System Event Log:
 The following log may recorded in System Event Log.
Source:
Type:
ID:
Description: [physical adapter name] Intel smart speed feature lowered the link speed than the
This event log is recorded when the initial link speed cannot be retained. Quality defect of cable or
noise may cause this event. Check the cable and connection status.
[?]
A Microsoft-Windows-MsLbfoSysEvtProvider warning log will be registered on the system event
log.
→ After a virtual switch has been created using the OS Standard NIC Teaming Function (LBFO), the
event log below may be registered when starting up or stopping the virtual machine, or when a
team member links up or links down.
Source:
Type:
Event ID:
Description: MAC conflict: A port on the virtual switch has the same MAC as one of the
This event occurs in order to select an external network when creating a Hyper-V virtual switch as
the virtual switch's destination, and in order to assign team members' MAC addresses to the virtual
switch if a NIC teamed team is selected on the network adapter.
No problems will occur during this operation when only one virtual switch port is in use or when this
event log is not outputted multiple times at once.
[?]
ESMCommonService related log is recorded in the system event log:
 Following event log is recorded while the system operation in some cases. The log indicates
detection of an event that is not critical event for the server operation, and the event is
amendable. This does not affect the system as long as the event never occurs repeatedly.
Source:
Type:
Event ID:
Description: ECC 1 bit error occurred on the system bus.
[?]
EvntAgnt log is recorded in the application event log:
 This event does not have any influence to the system not to SNMP services. Thus no
measurement is required.
Source:
Event ID:
Description: TraceFileName parameter not located in registry; Default trace file used is ???.
「Source:
Event ID:
Description: TraceLevel parameter not located in registry; Default trace level used is 32.
Express5800/R310e-E4, R320e-E4, R320e-M4, R310f-E4, R320f-E4, R320f-M4 Maintenance Guide (Windows)
108
srae1rexpress or sraixgbt
Warning
40
maximum speed.
Microsoft-Windows-MsLbfoSysEvtProvider
Warning
16945
underlying team members on Team Nic Microsoft Network Adapter Multiplexor
Driver.
ESMCommonService
Warning
1309
EvntAgnt
1003
EvntAgnt
1015
8. Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents