Enables echo cancellation for fax
Disables echo cancellation for modem
Performs certain jitter buffering optimizations
The network packets generated and received during the bypass period are regular voice
RTP packets (per the selected bypass coder), but with a different RTP payload type
according to the following parameters:
'Fax Bypass Payload Type' (FaxBypassPayloadType)
ModemBypassPayloadType (ini file)
During the bypass period, the coder uses the packing factor, configured by the 'Fax/Modem
Bypass Packing Factor' parameter (FaxModemBypassM). The packing factor determines
the
number
FaxModemBypassBasicRTPPacketInterval) that are used to generate a single fax/modem
bypass packet. When fax/modem transmission ends, the reverse switching, from bypass
coder to regular voice coder is performed.
To configure fax / modem bypass mode:
1.
Open the Gateway General Settings page (Setup menu > Signaling & Media tab >
Gateway folder > Gateway General Settings), and then from the 'Fax Signaling
Method' drop-down list (IsFaxUsed), select No Fax.
2.
On the Fax/Modem/CID Settings page, do the following:
a.
Set the 'Fax Transport Mode' parameter to Bypass (FaxTransportMode = 2).
b.
Set the 'V.21 Modem Transport Type' parameter to Enable Bypass
(V21ModemTransportType = 2).
c.
Set the 'V.22 Modem Transport Type' parameter to Enable Bypass
(V22ModemTransportType = 2).
d.
Set the 'V.23 Modem Transport Type' parameter to Enable Bypass
(V23ModemTransportType = 2).
e.
Set the 'V.32 Modem Transport Type' parameter to Enable Bypass
(V32ModemTransportType = 2).
f.
Set the 'V.34 Modem Transport Type' parameter to Enable Bypass
(V34ModemTransportType = 2).
3.
Set the ini file parameter, BellModemTransportType to 2 (Bypass).
4.
Configure the following optional parameters:
'Fax/Modem Bypass Coder Type' (FaxModemBypassCoderType).
'Fax Bypass Payload Type' (FaxBypassPayloadType).
ModemBypassPayloadType (ini file).
FaxModemBypassBasicRTPPacketInterval (ini file).
FaxModemBypasDJBufMinDelay (ini file).
Note:
When the device is configured for modem bypass and T.38 fax, V.21 low-
speed modems are not supported and fail as a result.