AudioCodes Mediant 800B User Manual page 1088

Gateway & enterprise sbc (e-sbc)
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

Parameter
Debug Level High Threshold
configure voip > sip-definition
settings > debug-level-high-
threshold
[DebugLevelHighThreshold]
Syslog Facility Number
[SyslogFacility]
CDR Syslog Sequence
Number
configure system > cdr > cdr-
seq-num
[CDRSyslogSeqNum]
Activity Types to Report via
Activity Log Messages
configure troubleshoot >
activity-log
[ActivityListToLog]
User's Manual
[1] Enable (default)
Defines the threshold (in percentage) for automatically switching to a
different debug level, depending on CPU usage. The parameter is
applicable only if the 'Syslog CPU Protection' parameter is enabled.
The valid value is 0 to 100. The default is 90.
The debug level is changed upon the following scenarios:
CPU usage equals threshold: Debug level is reduced one level.
CPU usage is at least 5% greater than threshold: Debug level is
reduced another level.
CPU usage is 5 to 19% less than threshold: Debug level is
increased by one level.
CPU usage is at least 20% less than threshold: Debug level is
increased by another level.
For example, assume that the threshold is set to 70% and the Debug
Level to Detailed (5). When CPU usage reaches 70%, the debug
level is reduced to Basic (1). When CPU usage increases by 5% or
more than the threshold (i.e., greater than 75%), the debug level is
disabled - No Debug (0). When the CPU usage decreases to 5% less
than the threshold (e.g., 65%), the debug level is increased to Basic
(1). When the CPU usage decreases to 20% less than the threshold
(e.g., 50%), the debug level changes to Detailed (5).
Note: The device does not increase the debug level to a level that is
higher than what you configured for the 'Debug Level' parameter.
Defines the Facility level (0 through 7) of the device's Syslog
messages, according to RFC 3164. This allows you to identify Syslog
messages generated by the device. This is useful, for example, if you
collect the device's and other equipments' Syslog messages, at one
single server. The device's Syslog messages can easily be identified
and distinguished from other Syslog messages by its Facility level.
Therefore, in addition to filtering Syslog messages according to IP
address, the messages can be filtered according to Facility level.
[16] = (Default) local use 0 (local0)
[17] = local use 1 (local1)
[18] = local use 2 (local2)
[19] = local use 3 (local3)
[20] = local use 4 (local4)
[21] = local use 5 (local5)
[22] = local use 6 (local6)
[23] = local use 7 (local7)
Enables or disables the inclusion of the sequence number (S=) in
CDR Syslog messages.
[0] Disable
[1] Enable (default)
Defines the operations (activities) performed in the Web interface
that are reported to a Syslog server.
[pvc] Parameters Value Change = Changes made on-the-fly to
parameters and tables, and Configuration file load. Note that the
ini file parameter, EnableParametersMonitoring can also be used
to set this option.
1088
Mediant 800B Gateway & E-SBC
Description
Document #: LTRT-10632

Advertisement

Table of Contents
loading

Table of Contents