AudioCodes Mediant 800B User Manual page 1323

Gateway & enterprise sbc (e-sbc)
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

User's Manual
Parameter
[RADIUSAccountingType]
AAA Indications
configure system > cdr >
aaa-indications
[AAAIndications]
RADIUS User Authentication Parameters
Use RADIUS for
Web/Telnet Login
configure system > radius
settings > enable-mgmt-
login
[WebRADIUSLogin]
Password Local Cache
Mode
configure system > radius
settings > local-cache-mode
[RadiusLocalCacheMode]
Password Local Cache
Timeout
configure system > radius
settings > local-cache-
timeout
[RadiusLocalCacheTimeout]
RADIUS VSA Access Level
Attribute
configure system > radius
settings > vsa-access-level
[RadiusVSAAccessAttribute]
RADIUS Servers Table
Version 7.2
[2] At Setup & Release = Sent at call setup and release.
Enables the Authentication, Authorization and Accounting (AAA)
indications.
[0] None = (Default) No indications.
[3] Accounting Only = Only accounting indications are used.
Enables RADIUS queries for Web and Telnet login authentication.
When enabled, logging into the device's Web and Telnet embedded
servers is done through a RADIUS server. The device communicates
with a user-defined RADIUS server and verifies the given username
and password against a remote database, in a secure manner.
[0] Disable (default)
[1] Enable
Note:
For RADIUS login authentication to function, you must also
configure the EnableRADIUS parameter to 1 (Enable).
RADIUS authentication requires HTTP basic authentication, where
the username and password are transmitted in clear text over the
network. Therefore, it's recommended to set the HTTPSOnly
parameter to 1 to force the use of HTTPS, since the transport is
encrypted.
Defines the device's mode of operation regarding the timer (configured
by the parameter RadiusLocalCacheTimeout) that determines the
validity of the username and password (verified by the RADIUS
server).
[0] Absolute Expiry Timer = When you access a Web page, the
timeout doesn't reset, instead it continues decreasing.
[1] Reset Timer Upon Access = (Default) Upon each access to a
Web page, the timeout always resets (reverts to the initial value
configured by RadiusLocalCacheTimeout).
Defines the time (in seconds) the locally stored username and
password (verified by the RADIUS server) are valid. When this time
expires, the username and password become invalid and a must be re-
verified with the RADIUS server.
The valid range is 1 to 0xFFFFFF. The default is 300 (5 minutes).
[-1] = Never expires.
[0] = Each request requires RADIUS authentication.
Defines the code that indicates the access level attribute in the Vendor
Specific Attributes (VSA) section of the received RADIUS packet.
The valid range is 0 to 255. The default is 35.
1323
72. Configuration Parameters Reference
Description
Mediant 800B Gateway & E-SBC

Advertisement

Table of Contents
loading