QuercusVL Programming Manual
There is an example available in the SmartLoop
Type/Data/Globals.ini"
6.1.2. Detectors configuration file
This file contains the configuration of the enabled detectors in the simulation. It corresponds to
the detectors configuration menu of a real SmartLoop
below refer to each parameter of the menu. See SmartLoop
information about it.
The file structure is fixed but parameters described maybe different depending on the
simulated detector. The file is divided into sections, defined between brackets, with their
parameters described below (one per line).
[Global]
NumDetectors=
[Detector1]
parameter1=value1
.
.
The first section (Globals) indicates the number of detectors to be described in the file. The
rest defines each of the detectors (Detector).
There is an example available in the SmartLoop
Type/Data/Detectors.ini"
6.1.2.1. Globals section
NumDetectors: number of defined detectors.
●
6.1.2.2. DetectorX section
Description of the detector; X indicates the detector identifier (from 1 to the total amount of
defined detectors). The structure changes depending on the detector type.
Common parameters.
Id: Detector identifier.
●
Type: detector type.
●
PRESENCE: presence detector.
○
Quercus Technologies
198
®
TS installation folder: "Simulation/Simulation
®
TS unit, so the parameters described
®
TS
®
TS installation folder: "Simulation/Simulation
user manual for detailed
®
Need help?
Do you have a question about the SmartLoop TS and is the answer not in the manual?