Configuration Messages - quercus SmartLoop TS Programming Manual

Table of Contents

Advertisement

QuercusVL Programming Manual
structure.

5.4. Configuration messages

5.4.1. SystemInfo
Version 0:
Query
The fields of the structure have the same meaning of the latest version, but the version of the
answer will depend on the version of this query.
Answer
4
1
1
1
4
15
18
64
MAC
BootTime
P. Name
Mah
Mhi
Rh
ProductionDate
Serial N.
The fields "FirmwareMajor", "FirmwareMinor" and "FirmwareRevision" don't exist. The fields
"HardwareMajor", "HardwareMinor" and "HardwareRevision" don't indicate the hardware
version, but the firmware version.
5.4.2. GetDetector
Versions 0, 1 and 2:
Query
The fields of the structure have the same meaning, but the version of the answer will depend
on the version of this query.
Answer
The structure related to the detector description has changed; the version of this message
defines the version of the detector structure. See the obsolete versions of each detector type.
5.4.3. SetPresenceDetector
Versions 0, 1 and 2:
Query
The structure related to the detector description has changed; version of this message defines
Quercus Technologies