QuercusVL Programming Manual
4.7. Query messages
4.7.1. VersionQuery
Query to receive information about the software running in a unit.
Query
Type: 32
●
Message Data: no message data.
●
Answer
Type: 64
●
Message Data:
●
Name[64]: product name. Characters not being used will be zero.
●
Major (Maj): major number of the version.
●
Minor (Min): minor number of the version
●
Revision (Rev): revision number of the version.
●
4.7.2. RealTimeQuery
Query to receive the last real time event generated at a specific detector.
Query
Type: 33
●
Message Data:
●
DetectorId: detector to which the query is requested .
●
Answer
Type: 65
●
Message Data:
●
Quercus Technologies
144
64
1
Name
Maj
4
DetectorId
1
1
Min
Rev
Need help?
Do you have a question about the SmartLoop TS and is the answer not in the manual?