QuercusVL Programming Manual
Only one of the two parameters can be used to specify the output actuator (Index or
OutputActuatorId); the parameter not used must be set to -1.
Answer
Type: 190
●
Message Data:
●
OutputActuator (OA): description of the output actuator using a structure
●
OutputActuator.
4.9.39. SetOutputActuator
Add or modify an output actuator in the configuration system.
Query
Type: 170
●
Message Data:
●
SessionId: session identifier obtained at the last valid "Login".
●
Action (Act): action :
●
0: modify the existing output actuator.
○
1: add a new output actuator.
○
OutputActuator
●
OutputActuator.
PeviousId: if an existing output actuator is modified, this parameter must
●
indicate the old identifier (can have been modified). On the other hand, if a new
output actuator is added, it must be set to -1.
Answer
ACK/NAK
Quercus Technologies
184
OA
4
2
SessionId
Act
(OA):
output
171
171
OA
PreviousId
actuator
description,
4
using
a
structure