Type
DetectorId
DetectorId: identifier of the detector that generated the real time event.
DetectorType (Type): type of detector that generated the real time event:
1: speed detector.
2: queue detector.
3: presence detector.
4: red light detector.
5: stopped car detector.
Timestamp: timestamp when the real time event was generated, using a
QuercusTimestamp structure.
Speed: approximated speed of the detected vehicle; in km/h.
Length: approximated length of the detected vehicle; in millimetres.
WrongWay (WW): true if the direction of the detected vehicle is incorrect, and
false if the direction is correct.
Occupation: occupancy percentage of the detector.
IsOccupied (IsOc): true if the detector reports vehicle presence, and false if free.
Field operational only in a presence detector.

4.7.3. StatusQuery

Query to receive the system status of the unit.
Query
Type: 34
Message Data: no message data
Answer
Type: 66
Message Data:
Quercus Technologies
145
8
1
Timestamp
4
4
Speed
Length
4
StartupTime
1
4
WW
Occupation
IsOc
1