rising-threshold

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
3344
rising-threshold percentage;
[edit snmp health-monitor]
Statement introduced before Junos OS Release 10.2 for J-EX Series switches.
The upper threshold is expressed as a percentage of the maximum possible value for
the sampled variable. When the current sampled value is greater than or equal to this
threshold, and the value at the last sampling interval is less than this threshold, a single
event is generated. A single event is also generated if the first sample after this entry
becomes valid is greater than or equal to this threshold. After a rising event is generated,
another rising event cannot be generated until the sampled value falls below this threshold
and reaches the
falling-threshold
—The lower threshold for the alarm entry.
percentage
Range:
through
1
100
Default:
percent of the maximum possible value
80
snmp—To view this statement in the configuration.
snmp-control—To add this statement to the configuration.
falling-threshold on page 3327
Configuring the Falling Threshold or Rising Threshold
.