Enable the continuity check protocol and specify the continuity check hold interval:
4.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain private maintenance-association private-ma]
user@switch1# set continuity-check hold-interval 1s
Configure the maintenance association end point (MEP):
5.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain private maintenance-association private-ma]
user@switch1# set mep 100 interface ge-1/0/1 auto-discovery direction down
Check the results of the configuration.
[edit]
user@switch1# show
protocols {
oam {
ethernet {
connectivity-fault-management {
maintenance-domain private {
level 0;
maintenance-association private-ma {
continuity-check {
interval 1s;
}
mep 100 {
interface ge-1/0/1;
auto-discovery;
direction down;
}
}
}
}
}
Configuring Ethernet OAM Connectivity Fault Management on Switch 2
To quickly configure Ethernet OAM CFM, copy the following commands and paste them
into the switch terminal window:
[edit protocols oam ethernet connectivity-fault-management maintenance-domain]
set name-format character-string
set maintenance-domain private level 0
set maintenance-association private-ma
set continuity-check hold-interval 1s
The configuration on switch 2 mirrors that on switch 2.
Specify the maintenance domain name format:
1.
[edit protocols oam ethernet connectivity-fault-management]
user@switch2# set name-format character-string
Specify the maintenance domain name and the maintenance domain level:
2.
[edit protocols oam ethernet connectivity-fault-management]
user@switch2# set maintenance-domain private level 0