Size
3
3.5
4
5
6
7
8
10
12
14
16
18
20
22
24
27
30
33
36
42
NOTES: 1. THESE TORQUE VALUES DO NOT APPLY TO CADMIUM PLATED FASTENERS
2. ALL TORQUE VALUES ARE STATIC TORQUE MEASURED PER STANDARD AUDIT
*3. ASSEMBLY USES HARDENED WASHER OR FASTENER IS PLACED AGAINST PLATED
4. CLAMP LOAD LISTED FOR SHCS IS SAME AS GRADE 8 OR CLASS 10.9 AND DOES NOT
3121166
Tensile
Clamp
(Dry or Loctite®
PITCH
Stress
Load
Area
Sq mm
KN
0.5
5.03
2.19
0.6
6.78
2.95
0.7
8.78
3.82
0.8
14.20
6.18
1
20.10
8.74
1
28.90
12.6
1.25
36.60
15.9
1.5
58.00
25.2
1.75
84.30
36.7
2
115
50.0
2
157
68.3
2.5
192
83.5
2.5
245
106.5
2.5
303
132.0
3
353
153.5
3
459
199.5
3.5
561
244.0
3.5
694
302.0
4
817
355.5
4.5
1120
487.0
METHODS TOLERANCE = ±10%
STEEL OR RAW ALUMINUM
REPRESENT FULL STRENGTH CAPABILITY OF SHCS. IF HIGHER LOAD IS REQUIRED,
ADDITIONAL TESTING IS REQUIRED.
Figure 1-5. Torque Chart (METRIC Fasteners - Sheet 5 of 7))
CLASS 8.8 METRIC BOLTS
CLASS 8 METRIC NUTS
Torque
Torque
Torque
(Loctite® 262
(Lub)
OR Vibra-
TM
263
)
TITE
[N.m]
[N.m]
[N.m]
1.3
1.0
2.1
1.6
3.1
2.3
6.2
4.6
11
7.9
18
13
26
19
50
38
88
66
140
105
126
219
164
197
301
226
271
426
320
383
581
436
523
737
553
663
1080
810
970
1460
1100
1320
1990
1490
1790
2560
1920
2300
4090
3070
3680
– JLG Lift –
SECTION 1 - SPECIFICATIONS
Torque
(Loctite®
TM
TM
TM
242
or 271
OR Vibra-
TM
TM
131)
TITE
111 or
140)
[N.m]
1.2
1.4
1.9
2.3
2.8
3.4
5.6
6.8
9.4
12
16
19
23
28
45
55
79
97
154
241
331
469
639
811
1130
1530
2090
2690
4290