JLG 1930ES Service Maintenance Manual page 135

Table of Contents

Advertisement

FLASH
HELP MESSAGE
CODE
3
2 CONTACTOR DRIVER PERMANENTLY ON
NOTE: Certain output driver problems cannot be detected because stimulation of the load could result in safety con-
cerns or annoyance (brake open circuit, lift down open circuit, ground alarm open circuit). 3-3 help messages
shall be latched until the next power cycle.
3
3 BRAKE SHORT TO BATTERY
3
3 BRAKE OPEN CIRCUIT
3
3 LIFT UP SHORT TO BATTERY
3
3 LIFT UP OPEN CIRCUIT
3
3 LIFT DN SHORT TO BATTERY
3
3 LIFT DN OPEN CIRCUIT
3
3 STEER LEFT SHORT TO BATTERY
3
3 STEER LEFT OPEN CIRCUIT
3121166
Table 5-2. Flash Code Listing
The Power Module's Line Contactor Drive Circuitry failed
to de-energize during power-up self-tests.
The Power Module is reporting a "Contactor Driver 1 Per-
manently On" Fault Code (23d). Refer to CANbus docu-
mentation for Power Module Message – Status.
Drive, Steer, & Lift Up Prevented.
Help messages with the 3-3 flash code indicate an output driver problem.
Voltage was detected on the brake solenoid when the out-
put driver was commanded off during power-up.
Brake INPUT driven Low AND Brake STAT detected Low
during power-up.
Drive, Steer, & Lift Prevented.
Current flow to the brake solenoid was not detected during
normal brake operation.
Brake INPUT driven High (normal operation) AND Brake
STAT detected Low.
Drive & Steer Prevented
Voltage was detected on the lift up solenoid when the out-
put driver was commanded off during power-up.
Lift Up INPUT driven Low AND Lift Up STAT detected Low
during power-up.
Drive, Steer, & Lift Up Prevented.
Current flow to the lift up solenoid was not detected during
power-up.
Lift Up INPUT driven High (momentarily) AND Lift Up STAT
detected Low during power-up.
No motion interlocks.
Voltage was detected on the lift down solenoid when the
output driver was commanded off during power-up.
Lift Down INPUT driven Low AND Lift Down STAT detected
Low during power-up.
No motion interlocks.
Current flow to the lift down solenoid was not detected dur-
ing normal lift down motion.
Lift Down INPUT driven High (normal operation) AND Lift
Down STAT detected Low.
Lift Up Prevented.
Voltage was detected on the steer left solenoid when the
output driver was commanded off during power-up.
Left Turn INPUT driven Low AND Left Turn STAT detected
Low during power-up.
Drive & Steer Prevented.
Current flow to the steer left solenoid was not detected dur-
ing power-up.
Left Turn INPUT driven High (momentarily) AND Left Turn
STAT detected Low during power-up.
Drive & Steer Prevented.
SECTION 5 - JLG CONTROL SYSTEM
CAUSE
– JLG Lift –
POSSIBLE RESOLVE
Refer to CANbus documenta-
tion for Power Module Mes-
sage - Status.
5-15