Machine Model Adjustment - Zapi - 1001092456 Power Module - JLG 1930ES Service Maintenance Manual

Table of Contents

Advertisement

SECTION 5 - JLG CONTROL SYSTEM

5.9 MACHINE MODEL ADJUSTMENT - ZAPI - 1001092456 POWER MODULE

Adjustment
DRIVE
ACCEL
DECEL
MINIMUM
MAXIMUM
ELEV. MAX.
LIFT
ACCEL
DECEL
UP MIN
UP MAX
DN MIN
DN MAX
STEER
STATIC
DRIVE
ACCELERATOR
FWD MIN
FWD MAX
REV MIN
REV MAX
GROUND
HORN
ALARM
LOAD
ACCY
OVR DBNCE
OVR HOLD
NOTE: These settings may change in order to achieve optimal performance on a machine by machine basis.
5-26
Table 5-4. Machine Model Adjustment
(Machines with ZAPI - 1001092456 Power Module Only)
Adjustment Range
1930ES
0.1 - 5.0 (Sec)
0.7
0.1 - 1.0 (Sec)
0.1
0 - 25%
0 -100%
100
0 - 25%
25
0.1 - 5.0 (Sec)
0.5
0.1 - 1.0 (Sec)
0.1
0 - 50%
20
0 - 100%
100
1 - 60%
45
1 - 100%
85
0 - 100%
70
0 - 100%
30
2.20 - 2.40 V
2.23
1.00 - 1.50 V
1.19
2.60 - 2.80 V
2.74
3.50 - 4.00 V
3.78
87 - 107 dB
107
87 - 107 dB
87
0 - 200 Kg
0.0 - 5.0 Sec
3.0
0.0 - 5.0 Sec
5.0
2030ES
0.7
0.1
0
0
100
25
0.5
0.1
20
100
45
85
70
30
2.23
1.19
2.74
3.78
107
87
0
0
3.0
5.0
– JLG Lift–
2630ES
2646ES
0.7
0.7
0.1
0.1
0
0
100
100
25
25
0.5
0.5
0.1
0.1
20
20
100
100
45
45
85
85
70
70
30
30
2.23
2.23
1.19
1.19
2.74
2.74
3.78
3.78
107
107
87
87
0
0
3.0
3.0
5.0
5.0
3246ES
0.7
0.1
0
100
25
0.5
0.1
20
100
45
85
70
30
2.23
1.19
2.74
3.78
107
87
0
3.0
5.0
1001115627-B
3121166

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2030es2630es3246es2646es2039es

Table of Contents