Filter with a non-renewable
element
Note:
Scania recommends that the filter should be re-
newed rather than cleaned.
• The filter may be cleaned a maximum of 3
times. Mark the filter after each time it has
been cleaned.
• Use a cleaning solution consisting of water
mixed with approx. 1% mild detergent.
1.
Pour the cleaning solution into the filter out-
let at the same time as turning the filter so
that the cleaning solution pours through the
filter against the direction of the air flow.
2.
Leave the filter in the cleaning solution for 5
minutes and then take it out so that all the
cleaning solution drains away.
3.
Rinse the filter with 30 litres of clean water
at a temperature of 30 to 40°C.
4.
Take out the element and allow the rinsing
water to drain off.
5.
Repeat this procedure until the rinsing water
is clean.
6.
Leave the element to dry in a warm place for
a few days.
Note:
The filter must not be dried with compressed air.
Renewing the safety cartridge
IMPORTANT!
When renewing the safety cartridge, take great
care to ensure that no dirt or other impurities get
into the engine. Do not remove the safety car-
tridge unnecessarily.
1.
Remove the cover from the air cleaner.
2.
Remove the filter element.
3.
Remove the safety cartridge.
4.
Fit a new, genuine safety cartridge.
5.
Renew or clean the filter element.
6.
Assemble the air cleaner.