Running

Check instruments and warning lamps at regular
intervals.
Engine speed range
600-750 rpm
Low idling up to 2,300 rpm
2,300-2,600 rpm
2,600-3,000 rpm
Limp home mode
If there is a fault in the normal throttle opening or
if CAN communication is interrupted, the fol-
lowing emergency operation option is provided:
A CAN fault or throttle opening fault in an all-
speed engine (both signal and idling switch):
• The throttle opening value is 0% and the en-
gine is running at normal idling speed.
• The throttle opening value is 0% and the en-
gine is running at raised idling speed (750
rpm) if this function is activated.
Throttle opening fault, but the idling switch is
working:
• The throttle opening value can be increased
slowly between 0 and 50% by using the idling
switch.
CAN fault:
• The engine is switched off if the shutdown
function is activated.
OPM 250 en-GB
Low idling. Engine idling is controlled by the engine manage-
ment system.
The engine operating speed range, depending on power class.
Unsuitable operating speed, but a slightly higher engine speed
than the normal maximum operating speed may occur when
load is low or negative.
Prohibited engine speed.
21
© Scania CV AB 2016, Sweden
Starting and running