Antifreeze and corrosion inhibitor con-
centration table
35% by volume of Scania antifreeze provides
sufficient protection against corrosion.
Example:
1.
The total volume of the cooling system is 40
litres in this example.
2.
The measured concentration of ethylene gly-
col is 35% by volume (freezing point -21
°C). According to the table there are 14 litres
of ethylene glycol in the cooling system.
3.
The required concentration of ethylene gly-
col is 45% by volume (freezing point -30
°C). According to the table, 18 litres of eth-
ylene glycol are required in the cooling sys-
tem.
4.
Since there are already 14 litres in the cool-
ing system, 4 litres of ethylene glycol must
be added to the cooling system (18 - 14 = 4
litres).
Volume of ethylene glycol
(%)
Ice slush forms (°C)
Volume of ethylene glycol (li-
tres)
OPM 250 en-GB
For calculation
Adequate protection against corrosion
20
25
30
-6
-9
-12
5
6
8
6
8
10
8
10
13
9
12
15
11
14
18
12
16
20
14
18
23
15
20
25
17
22
28
18
24
30
20
26
33
21
28
35
23
30
38
24
32
40
26
34
43
27
36
45
29
38
48
30
40
50
42
© Scania CV AB 2016, Sweden
35
40
45
50
-21
-24
-30
-38
11
12
14
15
14
16
18
20
18
20
23
25
21
24
27
30
25
28
32
35
28
32
36
40
32
36
41
45
35
40
45
50
39
44
50
55
42
48
54
60
46
52
59
65
49
56
63
70
53
60
68
75
56
64
72
80
60
68
77
85
63
72
81
90
67
76
86
95
70
80
90
100
Cooling system
Cooling system
60
volume (litres)
-50
18
30
24
40
30
50
36
60
42
70
48
80
54
90
60
100
66
110
72
120
78
130
84
140
90
150
96
160
102
170
108
180
114
190
120
200

Hide quick links: