Connecting the mains cable

General
If no mains cable is connected, a mains cable that is suitable for the connection voltage
must be fitted before commissioning.
A universal strain-relief device for cable diameters from 14 - 16 mm (0.55 - 0.63 in.) is fitted
to the power source.
Strain-relief devices for other cable cross-sections must be designed accordingly.
Stipulated mains
Power source
cables
TPS 320i nc
TPS 400i nc
TPS 500i nc
*
AWG = American wire gauge
Select a strain-relief device based on the cable required.
Connecting the
mains cable -
general
IMPORTANT! The ground conductor should be approx. 30 mm (1.18 in.) longer than the
phase conductors.
1
42
Mains voltage
3 x 400 V
3 x 460 V
3 x 400 V
3 x 460 V
3 x 400 V
3 x 460 V
Cable type for USA / Canada: Extra-hard usage
CAUTION! Risk of injury and material damage due to short circuits.
Short circuits can occur between the phase conductors or between the phase
conductors and the ground conductor unless ferrules are used.
Fit ferrules to all phase conductors in an exposed mains cable as well as the
ground conductor.
NOTE! Mains cables must be connected to devices in compliance with national
standards and guidelines and the work must be carried out by a qualified person.
Cable cross-section
USA / Canada *
Europe
AWG 12
4G 2.5 mm²
AWG 14
4G 2.5 mm²
AWG 10
4G 4.0 mm²
AWG 12
4G 4.0 mm²
AWG 8
4G 4.0 mm²
AWG 10
4G 4.0 mm²
2