Tps 320I /Nc - Fronius TPS 320i Operating Instructions Manual

Mig/mag power source
Table of Contents

Advertisement

TPS 320i /nc

Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Mains fuse
Mains voltage tolerance
Mains frequency
Cos phi (1)
Max. permitted mains impedance Z
Recommended earth-leakage circuit breaker
Welding current range (I
MIG/MAG
Rod electrode
Welding current at
U
1
Output voltage range according to standard characteristic
(U
2
MIG/MAG
Rod electrode
Open circuit voltage (U
Degree of protection
Type of cooling
Overvoltage category
Pollution level according to IEC60664
EMC emission class
Safety symbols
Dimensions l x w x h
Weight
Max. shielding gas pressure
Coolant
Max. noise emission (L
1)
)
1
)
1max
)
2
10 min / 40 °C (104 °F)
= 380 - 460 V
)
peak / U
0
)
WA
Interface to a 230/400 V, 50 Hz public grid
3 x
)
1eff
1)
at PCC
max
r.m.s)
0
380 V
400 V
460 V
12.7 A
12.3 A
11.4 A
20.1 A
19.4 A
18.0 A
35 A slow-blow
+/- 15 %
50/60 Hz
0.99
95 mOhm
Type B
3 - 320 A
10 - 320 A
40 %
60 %
100 %
320 A
260 A
240 A
14.2 - 30.0 V
20.4 - 32.8 V
84 V
IP 23
AF
III
3
A
S, CE
706 x 300 x 510 mm
27.8 x 11.8 x 20.1 in.
35.0 kg
77.16 lb
7.0 bar
101.49 psi
Original Fronius
-
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tps 400iTps 500i

Table of Contents