TPS 400i /MV/nc

Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Mains fuse
Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Mains fuse
Mains voltage tolerance
Mains frequency
Cos phi (1)
Max. permitted mains impedance Z
Recommended earth-leakage circuit breaker
Welding current range (I
MIG/MAG
Rod electrode
Welding current at
U
1
U
1
Output voltage range according to standard characteristic
(U
2
MIG/MAG
Rod electrode
Open circuit voltage (U
Degree of protection
Type of cooling
Overvoltage category
Pollution level according to IEC60664
EMC emission class
Safety symbols
Dimensions l x w x h
Weight
Max. shielding gas pressure
Coolant
Max. noise emission (L
1)
)
1
)
1max
)
1
)
1max
)
2
10 min / 40 °C (104 °F)
= 200 - 230 V
= 380 - 460 V
)
peak / U
0
)
WA
Interface to a 230/400 V, 50 Hz public grid
3 x
)
1eff
3 x
)
1eff
1)
at PCC
max
r.m.s)
0
200 V
230 V
30.5 A
26.4 A
48.2 A
41.6 A
35 A slow-blow
380 V
400 V
460 V
16.2 A
15.5 A
14.0 A
25.5 A
24.4 A
22.1 A
35 A slow-blow
-10 / +15 %
50/60 Hz
0.99
75 mOhm
Type B
3 - 400 A
10 - 400 A
40 %
60 %
100 %
400 A
360 A
320 A
400 A
360 A
320 A
14.2 - 34.0 V
20.4 - 36.0 V
67 V
IP 23
AF
III
3
A
S, CE, CSA
706 x 300 x 510 mm
27.8 x 11.8 x 20.1 in.
- kg
- lb.
9.0 bar
130.49 psi