2. On the Events page, enter values for the parameters indicated in
Note
Web Page Item
Enable Event Generation
Events
Enable Call Start Events
Enable Call Terminated Events
Enable Relay Activated Events
Enable Relay Deactivated Events
Enable Night Ring Events
Enable Power On Events
Enable Multicast Start Events
Enable Multicast Stop Events
Enable Sensor Events
Enable 60 Second Heartbeat Events
Enable Singlewire Start Events
Enable Singlewire Stop Events
Check All
Uncheck All
Event Server
Server IP Address
Server Port
Server URL
Operations Guide
The question mark icon (
after the Toggle Help button is pressed
Table 2-19. Events Configuration Parameters
931251F
Installing the Singlewire InformaCast Speaker
) in the following table shows which web page items will be defined
.
Description
The device will send HTTP POST events to the specified remote
server and port number whenever a certain action takes place.
Select an event type below to generate an HTTP POST event.
When selected, the device will report the start of a SIP call.
When selected, the device will report the end of a SIP call.
When selected, the device will report relay activation.
When selected, the device will report relay deactivation.
When selected, the device will report when it starts ringing upon an
incoming SIP call to the Nightringer extension. As a reminder, the
Nightringer extension always rings upon an incoming SIP call and it
is not possible to alter this behavior.
When selected, the device will report when it boots.
When selected, the device will report when the device starts playing
a multicast audio stream.
When selected, the device will report when the device stops playing
a multicast audio stream.
When selected, the device will report when the on-board sensor is
activated.
When enabled, the device will report a Heartbeat event every 60
seconds. SIP registration is not required to generate Heartbeat
events.
When selected, the device will report when a Start event has been
received from the Singlewire server.
When selected, the device will report when a Stop event has been
received from the Singlewire server.
Click on Check All to select all of the events on the page.
Click on Uncheck All to de-select all of the events on the page.
The IPv4 address of the event server in dotted decimal notation.
Specify the event server port number. The supported range is 0-
65536. Enter up to 5 digits.
Generally, the destination URL is the name of the application that
receives the events and the string in the HTTP POST command. It
can be a script used to parse and process the HTTP POST events.
Enter up to 127 characters.
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.