Page 1
The IP Endpoint Company VoIP Indoor Intercom with Keypad (Flush-Mounted) Operations Guide Part #011123*, RAL 9003, Signal White Color *Replaces #011078 Document Part #930370I for Firmware Version 6.3.0 CyberData Corporation 3 Justin Court Monterey, CA 93940 (831) 373-2601...
Page 2
CyberData Corporation. This manual, and the products, software, firmware, and/or hardware described in this manual are the property of CyberData Corporation, provided under the terms of an agreement between CyberData Corporation and recipient of this manual, and their use is subject to that agreement and its terms.
Electrical Hazard: This product should be installed by a licensed electrician according to all local electrical and building codes. GENERAL ALERT Warning Electrical Hazard: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions. GENERAL ALERT CyberData Corporation 930370I Operations Guide...
Page 4
Potential safety hazards are identified in this manual through the use of words Danger, Warning, and Caution, the specific hazard type, and pictorial alert icons. CyberData Corporation 930370I Operations Guide...
Page 5
Table 2-10, "SIP Configuration Parameters" by adding the following settings: • SIP Server • Backup SIP Server 1 • Backup SIP Server 2 • Terminate call after delay (in seconds) • Updates Table 2-20, "Firmware Upgrade Parameters". Operations Guide 930370I CyberData Corporation...
C.4.2 Warranty & RMA Returns Outside of the United States ............ 69 C.4.3 Spare in the Air Policy ......................69 C.4.4 Return and Restocking Policy ....................70 C.4.5 Warranty and RMA Returns Page ..................70 Index Operations Guide 930370I CyberData Corporation...
Figure 1-1. The model number on the label should be 011123. Figure 1-1. Model Number Label WWW.CYBERDATA.NET VoIP INTERCOM WITH KEYPAD, INDOOR,FLUSH MNT,RAL 9003,RoHS 011123A / 021039G 123000001 Model number Operations Guide 930370I CyberData Corporation...
Electrical Hazard: This product should be installed by a licensed electrician according to all local electrical and building codes. GENERAL ALERT Warning Electrical Hazard: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions. GENERAL ALERT Operations Guide 930370I CyberData Corporation...
One dry contact relay for auxiliary control ● Autoprovisioning ● Configurable audio files ● Night Ringer ● Three year warranty ● Peer-to-peer capable ● Door closure and tamper alert signal ● Optional Torx screws with driver kit Operations Guide 930370I CyberData Corporation...
G711, A-law and µ-law Regulatory Compliance FCC Class A, UL 60950 Dimensions 6.5” x 4.5” x 1.5” (H x W x D) Warranty 2 years limited Part Number 011123 Auxiliary Relay 1A at 30 VDC Operations Guide 930370I CyberData Corporation...
Table 2-1 illustrates the parts for the VoIP Indoor Intercom with Keypad (Flush-Mounted). Table 2-1. Parts List Quantity Part Name Illustration VoIP Indoor Intercom with Keypad (Flush-Mounted) Assembly Installation Quick Reference Guide Mounting Accessory Kit Operations Guide 930370I CyberData Corporation...
3 = Normally Open Common 4 = Normally Open Contact Relay 5 = Door Sense Input (2A a 6 = Door Sense Ground Reference for c 3 = N 4 = N 5 = D 6 = D Operations Guide 930370I CyberData Corporation...
Such As Mechanical Electric Door Strike Relay Strobe Light Output Contacts AC or DC rated Depending Upon Controlled Device Requirements AC or DC Power Source POWER SUPPLY MAX. 30 VDC @ 1A Auxiliary Relay Wiring Contacts Operations Guide 930370I CyberData Corporation...
Table 2-4 to identify the connector locations and functions. Figure 2-3. Connector Locations Table 2-2. Connector Functions Connector Function PoE Network Connection (RJ-45 ethernet) Terminal Block (see Figure 2-1) RTFM (see Section 2.2.6, "RTFM Button") Operations Guide 930370I CyberData Corporation...
Page 16
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List Figure 2-4. Connector Locations Table 2-3. Connector Functions Connector Function LED Interface Microphone Interface Speaker Interface Keypad Interface Operations Guide 930370I CyberData Corporation...
Page 17
Audio Enable Factory only Phy Mode Not Used Phy Mode Not Used Phy Mode Not Used JP10 Intrusion Disable Jumper Placing a jumper on JP10 will disable the intrusion detection circuit. JP11 Option Jumper Not used Operations Guide 930370I CyberData Corporation...
When you plug in the Ethernet cable or power supply: • The square, green Link light above the Ethernet port indicates that the network connection has been established (see Figure 2-7). The Link light changes color to confirm the auto-negotiated baud rate: Operations Guide 930370I CyberData Corporation...
Page 19
This light is yellow at 10 Mbps. • It is orange at 100 Mbps. 2.2.5.1 Verify Network Activity The square, yellow Activity light blinks when there is network activity. Figure 2-7. Network Connector Activity Link Operations Guide 930370I CyberData Corporation...
The device will use DHCP to obtain the new IP address (DHCP-assigned address or default Note to 10.10.10.10 if a DHCP server is not present). Note Pressing and holding the RTFM button for longer than five seconds will restore the device to the factory default settings. Operations Guide 930370I CyberData Corporation...
The device will use DHCP to obtain the new IP address (DHCP-assigned address or default to 10.10.10.10 if a DHCP server is not present). Figure 2-9. RTFM Button RTFM 2.2.7 Adjust the Volume You can adjust the volume through the Device Configuration Page. Operations Guide 930370I CyberData Corporation...
Table 2-5. Factory Default Settings Parameter Factory Default Setting IP Addressing DHCP IP Address 10.10.10.10 Web Access Username admin Web Access Password admin Subnet Mask 255.0.0.0 Default Gateway 10.0.0.1 a. Default if there is not a DHCP server present. Operations Guide 930370I CyberData Corporation...
Link to the Sensor Configuration page. Link to the Multicast Configuration page. Link to the Audio Configuration page. Link to the Event Configuration page. Link to the Autoprovisioning Configuration page. Link to the Update Firmware page. Operations Guide 930370I CyberData Corporation...
Make sure that the PC is on the same IP network as the Intercom. Note You may also download CyberData’s VoIP Discovery Utility program which allows you to easily find and configure the default web address of the CyberData VoIP products.
Page 25
Parts List 2. When prompted, use the following default Web Access Username and Web Access Password to access the Home Page (Figure 2-10): Web Access Username: admin Web Access Password: admin Figure 2-10. Home Page Operations Guide 930370I CyberData Corporation...
Page 26
Keypad Mode is Shows the current Keypad Mode status. Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. Operations Guide 930370I CyberData Corporation...
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List 2.3.3 Configure the Device Parameters 1. Click the Device Configuration button to open the Device Configuration page. See Figure 2-11. Figure 2-11. Device Configuration Page Operations Guide 930370I CyberData Corporation...
Page 28
Click on the Test Audio button to do an audio test. When the Test Audio button is pressed, you will hear a voice message for testing the device audio quality and volume. Operations Guide 930370I CyberData Corporation...
Page 29
Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. 3. After changing the parameters, click the Save button. Operations Guide 930370I CyberData Corporation...
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List 2.3.4 Configure the Network Parameters 1. Click the Networking button to open the Network Configuration page (Figure 2-12). Figure 2-12. Network Configuration Page Operations Guide 930370I CyberData Corporation...
Page 31
Intercom if appropriate. 4. Connect the Intercom to the target network. 5. From a system on the same network as the Intercom, open a browser with the new IP address of the Intercom. Operations Guide 930370I CyberData Corporation...
Parts List 2.3.5 Configure the SIP Parameters 1. Click SIP Config to open the SIP Configuration page (Figure 2-13). Note For specific server configurations, go to the following website address: http://www.cyberdata.net/support/server/index.html Figure 2-13. SIP Configuration Page Operations Guide 930370I CyberData Corporation...
Page 33
Unregister on Reboot* When selected, on boot, the device will first register with a SIP server with a expiration delay of 0 seconds. This has the effect of unregistering any current devices on this extension. Operations Guide 930370I CyberData Corporation...
Page 34
Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. 3. After changing the parameters, click Save Settings. Operations Guide 930370I CyberData Corporation...
Page 35
There is no way to place a point-to-point call in Telephone Dial Mode or Cellphone Dial Mode. The Intercom can receive point-to-point calls in any mode. The delayed DTMF functionality is available in the Point-to-Point Mode. Note Note Establishing point-to-point SiP calls may not work with all phones. Operations Guide 930370I CyberData Corporation...
Page 36
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List Figure 2-14. SIP Configuration Page Set to Point-to-Point Mode Intercom is set to NOT register with a SiP server Operations Guide 930370I CyberData Corporation...
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List 2.3.6 Configure the Button Parameters 1. Click the Button Config button to open the Button Configuration page. See Figure 2-15. Figure 2-15. Button Configuration Page Operations Guide 930370I CyberData Corporation...
Page 38
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List Figure 2-16. Button Configuration Page (continued) Operations Guide 930370I CyberData Corporation...
Page 39
Keypad (0 through 9, *, and #) Enter the desired dial-out extension number (64 character limit). Note: For information about dial-out extension strings and DTMF tones, see Section 2.3.6.1, "Dial Out Extension Strings and DTMF Tones (using rfc2833)". Operations Guide 930370I CyberData Corporation...
Page 40
You can still use the # key but it is not necessary. For information about how to instantly triggering a dialout call or security code, see Section 2.3.6.2, "Triggering a Dialout Call or Security Code". Operations Guide 930370I CyberData Corporation...
Page 41
Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. 3. After changing the parameters, click the Save button. Operations Guide 930370I CyberData Corporation...
Page 42
Allow Telephone Dialout Option Disabled (in security mode with default security settings) Input Resulting Action Dialing 1234560 The device will activate the relay for Security Code 0 for 6 seconds. (and waiting for several seconds) Operations Guide 930370I CyberData Corporation...
The Nightringer is designed to be used in buildings where calls made after hours are directed to a ring group. 1. Click on the Nightringer button to open the Nightringer Configuration page. See Figure 2-17. Figure 2-17. Nightringer Configuration Setup Operations Guide 930370I CyberData Corporation...
Page 44
Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. 3. After changing the parameters, click on the Save button. Operations Guide 930370I CyberData Corporation...
• Loop an audio file out of the Intercom speaker until the sensor is deactivated • Call a preset extension and play a pre-recorded audio file (once) Note Calling a preset extension can be set up as a point-to-point call, but currently can't send delayed DTMF tones. Operations Guide 930370I CyberData Corporation...
Page 46
2. On the Sensor Configuration page, enter values for the parameters indicated in Table 2-15. Table 2-15. Sensor Configuration Parameters Web Page Item Description Door Sensor Settings Door Sensor Normally Closed Select the inactive state of the door sensors. Operations Guide 930370I CyberData Corporation...
Page 47
Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. 3. After changing the parameters, click Save Settings. Operations Guide 930370I CyberData Corporation...
Multicast configuration provides the ability to join up to 10 paging zones. A paging zone can consist of one, or many, CyberData multicast group-enabled devices. There is no limit to how many devices can be in a given paging zone. Each multicast group is defined by a multicast address and port number.
Page 49
SIP calls, multicast streams, ring tones, ringback tones, and nightring tones are all prioritized. Ringtones and Ringtones all play at the same priority level. This means that it is possible to have a nightring tone Nightringtones and a normal ringtone playing at the same time. Operations Guide 930370I CyberData Corporation...
The Audio Configuration page is used to add custom audio to the board. User uploaded audio will take precedence over the audio files shipped with the Intercom. 1. Click Audio Config to open the Audio Configuration page (Figure 2-20). Figure 2-20. Audio Configuration Page Operations Guide 930370I CyberData Corporation...
Page 51
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List Figure 2-21. Audio Configuration Page (continued) Operations Guide 930370I CyberData Corporation...
Page 52
'9' corresponds to the spoken word “nine.” Corresponds to the spoken word “dot.” (24 character limit) Audiotest Corresponds to the message “This is the CyberData IP speaker test message...” (24 character limit) Pagetone Corresponds to a simple tone used for beep on initialization and beep on page (24 character limit).
Page 53
The Save button will download a new user audio file to the board once you've selected the file by using the Browse button. The Save button will delete any pre-existing user- uploaded audio files. Operations Guide 930370I CyberData Corporation...
Page 54
RIFF (little-endian) data, WAVE audio, Microsoft PCM, 16 bit, mono 8000 Hz You can use the free utility Audacity to convert audio files into this format. See Figure 2-23 through Figure 2-25. Figure 2-23. Audacity 1 Figure 2-24. Audacity 2 Operations Guide 930370I CyberData Corporation...
Page 55
Parts List When you export an audio file with Audacity, save the output as: • WAV (Microsoft) signed 16 bit PCM. Figure 2-25. WAV (Microsoft) signed 16 bit PCM WAV (Microsoft) signed 16 bit PCM Operations Guide 930370I CyberData Corporation...
Click the Event Config button to open the Event Configuration page. The Event Configuration page specifies a remote server that can be used to receive HTTP POST events when actions take place on the board. Figure 2-26. Event Configuration Page Operations Guide 930370I CyberData Corporation...
Page 57
Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Test Event button to test an event. Click on the Reboot button to reboot the system. Operations Guide 930370I CyberData Corporation...
Page 58
Here are example packets for every event: POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 197 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'> <event>POWERON</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 199 Content-Type: application/x-www-form-urlencoded <?xml version="1.0"...
Page 59
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List User-Agent: CyberData/1.0.0 Content-Length: 205 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'> <event>CALL_TERMINATED</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 197 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>...
Page 60
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List User-Agent: CyberData/1.0.0 Content-Length: 234 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'> <event>RELAY_DEACTIVATED</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 234 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>...
Installing the VoIP Intercom with Keypad (Flush-Mounted) Parts List <cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'> <event>INTRUSION SENSOR</event> <index>8</index> </cyberdata> 2.3.12 Configure the Autoprovisioning Parameters 1. Click the Autoprovisioning button to open the Autoprovisioning Configuration page. Figure 2-27. Figure 2-27. Autoprovisioning Configuration Page...
Page 62
Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. 3. After changing the parameters, click the Save button. Operations Guide 930370I CyberData Corporation...
Page 63
The board gets its autoprovisioning information from an XML-formatted file hosted from a TFTP server. CyberData will provide a template for this XML file and the user can modify it for their own use.
Page 64
3. The board downloads and writes the firmware file again. CyberData has timed a firmware upgrade at 140 seconds. Therefore, if you suspect the board is stuck in a loop, either remove or comment out the FirmwareVersion line in the XML file and let the board boot as it normally does.
Page 65
You can force a change to the audio files on the board by clicking Restore Default on the Audio Configuration page or by changing the autoprovisioning file with “default” set as the file name. Operations Guide 930370I CyberData Corporation...
2.4 Upgrade the Firmware and Reboot the Intercom Note To guard against failed firmware upgrades, units shipped from CyberData with firmware version 5.1.2 and later feature a built-in "fail safe" mechanism. Note that field upgrading earlier units with v5.x.x will not allow for this feature.
Page 67
Shows the current firmware version. Use the Browse button to navigate to the location of the Intercom firmware file that you want to upload. Click on the Submit button to automatically upload the selected firmware and reboot the system. Operations Guide 930370I CyberData Corporation...
To reboot a Intercom, log in to the web page as instructed in Section 2.3.2, "Log in to the Configuration Home Page". 1. Click Reboot (Figure 2-29). A normal restart will occur. Figure 2-29. Reboot System Section Reboot Operations Guide 930370I CyberData Corporation...
--user admin --password admin --post-data "test_audio=yes" "http://10.0.3.78/cgi-bin/command.cgi" > /dev/null To cause the Intercom to speak wget --user admin --password admin --post-data it's ip address "speak_ip_address=yes" "http://10.0.3.78/cgi-bin/command.cgi" > /dev/null a.Type and enter all of each http POST command on one line. Operations Guide 930370I CyberData Corporation...
#6 X 3/8-inch,100 Degrees, Flat Head Countersunk, Self-Tapping Screw Table A-2. Optional Mounting Components (Part of the Accessory Kit) Quantity Part Name Illustration #6 X 3/8-inch,100 Degrees, Security Torx, Self-Tapping Screw T15 Security Torx Key Operations Guide 930370I CyberData Corporation...
Page 71
4. Install the gang box into the wall cutout. 5. Tighten the four flag nuts with a Phillips screwdriver. 6. Place the Intercom over the gang box. 7. Secure the Intercom to the gang box with the four mounting screws. Operations Guide 930370I CyberData Corporation...
1. Install and start the software. 2. Select File Configure Security tab Transmit Only. 3. Make a note of the default directory name, and then move the firmware files to be uploaded to that directory. Operations Guide 930370I CyberData Corporation...
2. Go to the support page for your product, and click on the FAQs tab. C.2 Documentation The documentation for this product is released in an English language version only. You can download PDF copies of CyberData product documentation by doing the following: 1. Go to the following URL: http://www.cyberdata.net/products/voip/digitalanalog/intercomkeypadflush/docs.html 2.
3 Justin Court Monterey, CA 93940 Attention: RMA "your RMA number" RMA Status Form If you need to inquire about the repair status of your product(s), please use the CyberData RMA Status form at the following web address: http://www.cyberdata.net/support/rmastatus.html Operations Guide...
C.4.3 Spare in the Air Policy CyberData now offers a Spare in the Air no wait policy for warranty returns within the United States and Canada. More information about the Spare in the Air policy is available at the following web address: http://www.cyberdata.net/support/warranty/spareintheair.html...
For End Users, please contact the company that you purchased your equipment from for their return policy. C.4.5 Warranty and RMA Returns Page The most recent warranty and RMA information is available at the CyberData Warranty and RMA Returns Page at the following web address: http://www.cyberdata.net/support/warranty/index.html...
(intrusion sensor) 41 connector locations 9, 10, 11 address, configuration login 18 contact information 68 alternative power input 4, 7 contact information for CyberData 68 announcing a device’s IP address 14 current network settings 25 audio configuration 44 CyberData contact information 68...
Page 79
68 resetting the IP address to the default 64 technical support, contact information 68 restoring factory default settings 15, 71 terminal block, 16 AWG gauge wire 7 restoring the factory default settings 15 Operations Guide 930370I CyberData Corporation...
Page 80
& RMA returns outside of the United States 69 warranty & RMA returns within the United States 69 warranty and RMA returns page 70 warranty policy at CyberData 69 web access password 16 web access username 16 web configuration log in address 18...
Need help?
Do you have a question about the 011123 Series and is the answer not in the manual?
Questions and answers