6. Guide light
Setting-out measurement etc. can be carried out effectively using the guide light.
The guide light is composed of a light that is divided into a red and a green light. A
poleman can ascertain whether to move to the right or left by checking the guide
light color.
"14.2 Using the Guide Light"
7. Sighting the target and performing distance measurement using Auto Pointing
Use the peep sight to bring the target roughly into the field of view. Then, press
[SRCH] to automatically sight the center of the target. The instrument and telescope
can be rotated manually by hand or, for more precise adjustments, by turning the
vertical and horizontal jogging knobs.
The instrument can be set to automatically measures the distance after Auto
Pointing has been completed. The search range can be set beforehand.
"11.2 Auto-Pointing Function for Target Sighting" and "21.3 EDM Settings"
8. Trigger Key for Easier Operation
Each screen contains a number of softkeys. Softkeys displayed in bold type control
the flow of measurement operation. Pressing the trigger key located on the side of
the SRX will perform exactly the same operation as the bolded softkey in the current
screen. This allows the user to continue operation without having to return to the
display to press softkeys, making operations such as resection measurement even
simpler.
"4.2 Parts of the Instrument  Trigger key"
9. Wide range of advanced programs
One touch of the {PROGRAM} key allows the user to switch from Basic mode to
Program mode (SDR) in order to use advanced measurement programs. The
position of menus and softkeys can be user-defined for greater ease-of-use.
Switching modes: "4.3 Mode Configuration", rearranging softkeys:
"21.6 Allocating Key Functions"
10. SETTINGS Mode
One-touch of the {SETTINGS} key allows the user to jump to and from the
SETTINGS mode during operation without exiting measurement.
"4.3 Mode Configuration"
11.Sokkia's original Independent Angle Calibration System (IACS) technology
Unaffected by errors in collimation and instrument setup, this internal calibration
technology provides an even higher level of stability and reliability for angle
measurement.
Independent angle calibration cannot be performed by the user. Consult your
Sokkia agent.
4. PRODUCT OUTLINE
9