Rem Measurement; Distance Measurement And Outputting The Data - Sokkia SRX1 Operator's Manual

Series srx surveying instruments
Table of Contents

Advertisement

14. DISTANCE MEASUREMENT
14.4

Distance Measurement and Outputting the Data

The following explains distance measurement and the features used to output measurement data to
a computer or external devices.
"8. CONNECTING TO EXTERNAL DEVICES", Communication cables: "27. OPTIONAL
ACCESSORIES". Output format and command operations: Interfacing with the SOKKIA SDR
Electronic Field Book and Command Explanations manuals
PROCEDURE
1. Connect SRX and external device.
2. Sight the target point.
3. Press [HVD out] in Meas mode to start distance
measurement. Target measurement results are
output to the external device.
Output type: "21.6 Allocating Key Functions",
"21.1 Observation Conditions"
4. Press [STOP] to finish data output and return to
the Meas mode.
14.5

REM Measurement

An REM measurement is a function used to measure the height to a point where a target cannot be
directly installed such as power lines, overhead cables and bridges, etc.
The height of the target is calculated using the following formula.
Ht = h
+ h
1
2
h2 = S sin
x cot
z1
z2
Zenith
Zenith
• It is possible to allocate softkeys in the REM measurement menu to suit various applications and
the ways that different operators handle the instrument.
70
- S cos
z1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srx2Srx3Srx5

Table of Contents