17. SETTING-OUT MEASUREMENT
4. Select "SO data setting" In <Setting out> to
display <SO data setting>. Enter the included
angle between the reference point and the
setting-out point in "SO.H.ang", and the distance
(slope distance, horizontal distance or height
difference) from the instrument station to the
position to be set out in "SO.Sdist". Enter the
value in the Distance mode that conforms to your
measurement requirements.
• Each time [/Shvr] is pressed, the distance input
mode changes from "S" (slope distance), "H"
(horizontal distance), "V" (height difference), and
"Ht." (REM).
• When [READ] is pressed, coordinates
registered in Program mode (SDR) can be
recalled and used. The distance selected
according to the selected distance input mode is
calculated using these coordinate values.
Series SRX SDR Software Reference
Manual
• Press [COORD] in the second page and input
coordinates in <Key in coord>. The angle and
distance from these coordinates to the position
to be set out will be calculated.
5. Enter values and press [OK] to display the
screen at right.
Press [H.ROTA] to automatically rotate the SRX
toward the horizontal angle set in step 3 and set
the angle to the setting out point to 0°.