Panasonic fp2/fp2sh User Manual page 323

Programmable controller
Table of Contents

Advertisement

Name
Boolean
Push stack
PSHS
Read stack
RDS
Pop stack
POPS
Leading edge
DF
differential
Trailing edge
DF/
differential
Leading edge
DFI
differential
(initial execution
type)
Set
SET
Reset
RST
Keep
KP
No operation
NOP
Basic function instructions
On-delay timer
TML
TMR
TMX
TMY
Auxiliary timer
F137
(16-bit)
(STMR)
Auxiliary timer
F183
(32-bit)
(DSTM)
Time constant
F182
processing
Counter
CT
: Available,
: Not available,
*1) The type of the devices that can be specified depends on the models.
*2) The allowable number of using the PSHS and RDS instruction depends on the models.
*3) For FP2SH, FP10SH and FP-X Ver2.0 or later, any device can be set for the setting value of counter or timer instruction.
*4) This instruction is available for FP-X Ver. 2.0 or later.
*5) In the FP2/FP2SH/FP10SH, when using Y1280, R1120 (special internal relay included), L1280 or anything beyond for the
KP instruction, the number of steps is shown in parentheses. Also, in the FP2/FP2SH/FP10SH, when a relay number has
an index modifier, the number of steps is shown in parentheses.
*6) In the FP2/FP2SH/FP10SH, when timer 256 or higher, or counter 255 or lower, is used, the number of steps is the number
in parentheses. Also, in the FP2/FP2SH/FP10SH, when a timer number or counter number has an index modifier, the
number of steps is the number in parentheses. For the FPΣ and FP-X, the number of steps varies according to the
specified timer number or counter number.
Symbol
Stores the operated result up to this
instruction. *2
Reads the operated result stored by
the PSHS instruction. *2
Reads and clears the operated result
stored by the PSHS instruction
Turns on the contact for only one
scan when the leading edge of the
trigger is detected.
Turns on the contact for only one
scan when the trailing edge of the
trigger is detected.
Turns on the contact for only one
scan when the leading edge of the
trigger is detected. The leading edge
detection is possible on the first scan.
Output is set to and held at on.
Output is set to and held at off.
Outputs at set trigger and holds until
reset trigger turns on.
No operation.
After set value "n" x 0.001 seconds,
timer contact "a" is set to on.
After set value "n" x 0.01 seconds,
timer contact "a" is set to on.
After set value "n" x 0.1 seconds,
timer contact "a" is set to on.
After set value "n" x 1 second, timer
contact "a" is set to on.
After set value "S" x 0.01 seconds,
the specified output and R900D are
set to on.
After set value "S" x 0.01 seconds,
the specified output and R900D are
set to on.
Executes the filter processing for the
specified input.
Decrements from the preset value "n"
: Not available partially
Description
1
1
1
1
1
1
3
3
1
(2)
1
3
(4)
3
(4)
3
(4)
4
(5)
5
7
9
3
(4)
11-55
*3
*3
*3
*3
*3