Installing the Access Point on the Ceiling T-Rail
To install the access point on the celling T-rail, perform the following
procedure:
1. Read "Reviewing Safety Precautions" on page 28.
2. Review "Guidelines for Installing the AT-MWS600AP or
AT-MWS1750AP Access Point" on page 46.
3. Attach two rail clips and the spacers to the access point using the long
screws as shown in Figure 27.
Figure 27. Attaching the Rail Clips and Spacers to the Access Point
4. Connect an Ethernet cable. See "Connecting the Access Point with the
Ethernet Cable" on page 53.
Note
Ensure the cable is long enough to connect the access point to the
place where you planned. Once the access point is installed, it may
be difficult to change the cable.
5. If you plan to use the AC adapter, connect it. See "Connecting the AC
Adapter" on page 54.
Note
Ensure the power outlet is in the reach. Once the access point is
installed, it may be difficult to change the location.