IBM totalstorage 2109 M12 Installation And Service Manual page 42

San switch
Hide thumbs Also See for totalstorage 2109 M12:
Table of Contents

Advertisement

10. Optional: Specify any custom status policies.
11. Add SFPs and cables to the Fibre Channel ports, as required.
12
IBM TotalStorage SAN Switch: 2109 Model M12 Installation and Service Guide
3) Log in as admin.
4) Repeat step 8a on page 11 and step 8b on page 11 for the other
logical switch.
9. Optional: Modify the domain IDs, if desired.
Type fabricShow to see a list of the current domain IDs.
Note: The default domain ID for both switches is 1. To prevent a domain ID
conflict, make the domain IDs unique before you connect the switches
to the fabric.
a. Type the following command to disable the switch:
switchDisable
b. Type the following command:
configure
c. Type y at the Fabric parameters prompt:
Fabric parameters (yes, y, no, n): [no] y
d. Type a unique domain ID at the Domain prompt:
Domain: (1..239) [1] 3
e. Complete the remaining prompts or press CTRL+D to accept the other
settings and exit.
f. Type the following command to re-enable the switch:
switchEnable
a. To access the status policy, type the following command at the prompt:
switchStatusPolicySet
b. Complete the prompts to specify the status policies. To completely
deactivate the alarm for a particular condition, type 0 at the prompt for that
condition.
Note: The ports are color-coded to indicate which ones can be used in the
same trunking groups. Four ports that are marked with black solid ovals
alternate with four ports that are marked with oval outlines. The ports
and cables that are used in trunking groups must meet specific
requirements. For a list of these requirements, see the IBM TotalStorage
SAN Switch 2109 Model M12 User's Guide and the Brocade ISL
Trunking User's Guide.
a. Position one of the SFPs so that the key is oriented correctly to the port.
Insert the SFP into the port until it is firmly seated. Ensure that the latching
mechanism clicks.
Note: SFPs are keyed so that you can only insert them with the correct
orientation. If an SFP does not slide in easily, ensure that it is
correctly oriented. For instructions that are specific to the SFP
model, see the documentation of the SFP manufacturer.
b. Position a cable so that the key (the ridge on one side of the cable
connector) aligns with the slot in the SFP. Insert the cable into the SFP
until the latching mechanism clicks.

Advertisement