IBM totalstorage 2109 M12 Installation And Service Manual page 101

San switch
Hide thumbs Also See for totalstorage 2109 M12:
Table of Contents

Advertisement

The message HA-state in sync also displays. If not, POST is not
complete or the CP cards have not yet achieved redundancy. Wait a
minute and re-run the command until you can verify that redundancy has
been achieved. See the sample output from the hashow command before
redundancy is achieved.
SW1:admin> haShow
Local CP (Slot 5, CP0): Active
Remote CP (Slot 6, CP1): Standby, Healthy
HA enabled, Heartbeat Up, HA State not in sync
SW1:admin>
2. Run the slotshow command. The command output should show the new CP
card as enabled, as the following output shows.
SW1:admin> slotShow
Slot Blade Type ID Status
---------------------------------
1 SW BLADE 2 ENABLED
2 SW BLADE 2 ENABLED
3 SW BLADE 2 ENABLED
4 SW BLADE 2 ENABLED
5 CP BLADE 1 ENABLED
6 CP BLADE 1 ENABLED
7 SW BLADE 2 ENABLED
8 SW BLADE 2 ENABLED
9 SW BLADE 2 ENABLED
10 SW BLADE 2 ENABLED
SW1:admin>
3. Determine the firmware version. For Fabric OS v4.0 and earlier, run the
version command. For Fabric OS v4.0c and later firmware, run the
firmwareshow command. Sample output for the version command and the
firmwareshow command follows.
SW1:admin> version
Kernel: 2.4.2
Fabric OS: v4.0.0
Made on: Fri Feb 1 23:02:08 2002
Flash: Fri Feb 1 18:03:35 2002
BootProm: 3.1.13b
SW1:admin>
SW1:admin> firmwareshow
Local CP (Slot 5, CP0): Active
Primary partition: v4.0.2
Secondary Partition: v4.0.2
Remote CP (Slot 6, CP1): Standby
Primary partition: v4.0.2
Secondary Partition: v4.0.2
SW1:admin>
4. If the firmware versions on the replacement card do not match the active CP
card, bring the replacement card to the same firmware level as the active card.
a. Download the firmware from the following Web site:
www.ibm.com/servers/storage/support/san/2109m12.html
Chapter 6. Servicing the M12
71

Advertisement

Table of Contents
loading

Table of Contents